CIVILICA We Respect the Science
Publisher of Iranian Journals and Conference Proceedings
Paper
title

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

Credit to Download: 1 | Page Numbers 9 | Abstract Views: 34
Year: 2007
COI code: JR_IRJNM-15-2_005
Paper Language: English

How to Download This Paper

For Downloading the Fulltext of CIVILICA papers please visit the orginal Persian Section of website.

Authors Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Kourosh Ebrahim Nejad Gorgi - Department of Medical Physics, Tarbiat Modares University, Tehran, Iran
  Hossein Rajabi - Department of Medical Physics, Tarbiat Modares University, Tehran, Iran
  Ebrahim Hajizadeh - Department of Biostatistics, Tarbiat Modares University, Tehran, Iran
  Faraz Kalantari - Department of Medical Physics, Tarbiat Modares University, Tehran, Iran

Abstract:

 
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent lesion size and shape and reducing both signal and signal-to-noise ratio levels
Methods: 4D average male torso (2 cm diaphragmatic motion) produced by NCAT phantom was used for simulations. Emission sinograms generated by Eidolon PET simulator were reconstructed using iterative algorithm using STIR. The respiratory motion correction (RMC) applied to data sets using an automatic algorithm. Cross section views, activity profiles, contrast-to-noise ratios and left ventricle myocardium widths of corrected and non-corrected images were compared to investigate the effect of applied correction.
Results: Comparison of respiratory motion corrected and non corrected images showed that the algorithm properly restores the left ventricle myocardium width, activity profile and improves contrast-to-noise ratios in all cases.  Comparing the contrast recovery coefficient ( )shows that the applied correction effected phases of number 7,8 and 9 of cardiac cycle more than the other  13 phases and  the maximum value being 1.43±0.07 for phase number 8. The maximum value of ratio of the left ventricle myocardium width for non-RMC and RMC images along the line profile passing the apicobasal direction and along the line profile passing from the middle of the lateral wall of the left ventricle were 1.38±0.07 for phase number 9 and 1.12±0.03 for phases of number 8 and 9 respectively.
Conclusion: Blurring and ghosting of each image depends on the speed of diaphragm during that respiratory phase. This simulation study demonstrates that respiratory motion correction has good overall effect on PET cardiac images and can reduces errors originating from diaphragmatic motion and deformation. Effect of such a correction varies from one cardiac phase to another and this depends on the blurring and ghosting of all respiratory phases used to form this cardiac phase. Using an automatic algorithm capable of correcting respiratory motion using full signal may be very useful to prevent lengthening of the overall scan time to obtain same motionless lesion signal levels.

Keywords:

PET, Cardiology, Eidolon, Monte Carlo, Respiratory motion

Perma Link

https://www.civilica.com/Paper-JR_IRJNM-JR_IRJNM-15-2_005.html
COI code: JR_IRJNM-15-2_005

how to cite to this paper:

If you want to refer to this article in your research, you can easily use the following in the resources and references section:
Ebrahim Nejad Gorgi, Kourosh; Hossein Rajabi; Ebrahim Hajizadeh & Faraz Kalantari, 2007, Reducing the respiratory motion artifacts in PET cardiology: A simulation study, Iranian Journal of Nuclear Medicine 15 (2), https://www.civilica.com/Paper-JR_IRJNM-JR_IRJNM-15-2_005.htmlInside the text, wherever referred to or an achievement of this article is mentioned, after mentioning the article, inside the parental, the following specifications are written.
First Time: (Ebrahim Nejad Gorgi, Kourosh; Hossein Rajabi; Ebrahim Hajizadeh & Faraz Kalantari, 2007)
Second and more: (Ebrahim Nejad Gorgi; Rajabi; Hajizadeh & Kalantari, 2007)
For a complete overview of how to citation please review the following CIVILICA Guide (Citation)

Scientometrics

The University/Research Center Information:
Type: state university
Paper No.: 25732
in University Ranking and Scientometrics the Iranian universities and research centers are evaluated based on scientific papers.

Research Info Management

Export Citation info of this paper to research management softwares

New Related Papers

Iran Scientific Advertisment Netword

Share this paper

WHAT IS COI?

COI is a national code dedicated to all Iranian Conference and Journal Papers. the COI of each paper can be verified online.