The Study of Performance Comparison of Flat Plate and Evacuated Tube Collectors for Domestic Hot Water Heating Systems in Kerman

Credit to Download: 1 | Page Numbers 7 | Abstract Views: 23
Year: 2018
COI code: CLEANENERGY06_018
Paper Language: English

How to Download This Paper

For Downloading the Fulltext of CIVILICA papers please visit the orginal Persian Section of website.

Authors The Study of Performance Comparison of Flat Plate and Evacuated Tube Collectors for Domestic Hot Water Heating Systems in Kerman

Hadi Farzan - Mechanical Engineering Department, Higher Educational Complex of Bam, 76615-314, Bam, Iran

Abstract:

This study represents a year round energy performance of two solar water heater (SWH) systems with 4m2 flat plate collector (FPC) and evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on monthly and yearly basis. The obtained results showed that for an annual total solar insolation of 2056kWhm2 , the total of 3577kWhy 1 and 4201kWhy 1 heat energy were collected by 4m2 FPC and ETC systems, respectively. The annual average efficiency by FPC system was 43%, while its annual solar fraction was 50%. The ETC system had 51% efficiency with 58% solar fraction. The economic analysis showed that both solar water heating system are not economically viable under prevailing costs in Iran. Furthermore, according to the obtained results the FPCs are more favorable than the ETCs due to its economic analysis and energy performance. These results provide useful information for households and policy makers.

Keywords:

Plat plate collector, Evacuated tube collector, Energy performance analysis, Economic analysis, Solar water heater, Solar fraction

Perma Link

https://www.civilica.com/Paper-CLEANENERGY06-CLEANENERGY06_018.html
COI code: CLEANENERGY06_018

how to cite to this paper:

If you want to refer to this article in your research, you can easily use the following in the resources and references section:
Farzan, Hadi, 2018, The Study of Performance Comparison of Flat Plate and Evacuated Tube Collectors for Domestic Hot Water Heating Systems in Kerman, 6th Annual Clean Energy Conference, شيراز, دانشگاه شيراز - دانشگاه تحصيلات تكميلي صنعتي و فناوري پيشرفته كرمان, https://www.civilica.com/Paper-CLEANENERGY06-CLEANENERGY06_018.htmlInside the text, wherever referred to or an achievement of this article is mentioned, after mentioning the article, inside the parental, the following specifications are written.
First Time: (Farzan, Hadi, 2018)
Second and more: (Farzan, 2018)
For a complete overview of how to citation please review the following CIVILICA Guide (Citation)