Abstract:

The apex locators are used for measuring the canal length of the tooth root, based on the estimation of the tooth electrical impedance. This measurement is the most sensitive step in the Endodontic treatment procedure of a tooth via electronic apex locators (EAL). Radiography was the most commonly and widely used technique for root canal length determination. However recently, EALs are widely utilized for the measurement.In this paper, an apex locator which is based on estimating equivalent circuit and impedance of human tooth is designed and implemented. EAL uses 1 and 10 Kilo Hertz (KHz) frequencies for measuring the depth of the tooth root canal according to tooth impedances in these two frequencies. The measurement results confirm the high performance of the implemented EAL

Keywords:

Electronic apex locator , ERCLMD , Root canal depth measurement , Electrical impedance of tooth , Equivalent circuit of tooth , Endodontic

Authors

Moosa Ayati

School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran

Parisa Niknafs

M.Sc. Student of Electrical Engineering

Amirhosein Zourintan

M.Sc. Student of Electrical Engineering

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Gordon, M and Chandler, N. (2004). Electronic apex locators. International ...
  • Ahmad, _ and Pan , S. i. (2015). Accuracy of ...
  • Ebrahim, A. K. Wadachi, R. Suda, H. Electronic apex locatorsa ...
  • B ahrololoomi, Z. Soleymani, A. Modaresi, A. J. Imanian, M. ...
  • Sunada, I. (1962). New method for measuring the length of ...
  • Nekoofar, M. Ghandi, M. Hayes, S and Dummer, P. (2006). ...
  • Baugh, D. Wallace, J. (2005). The role of apical instrumentati ...
  • Marjanovic, _ Lackovic, I. Stare, Z. (2011). Comparison of electrical ...
  • Kang, J. A. Kim, S. K. (2008). Accuracies of seven ...
  • Stare, Z. Sutalo, J. and Galic, N. (1998). The effect ...
  • Macdonald, J. R. Barsoukov, E. (2005). Impedance spectroscopy: theory. experiment ...
  • Plotino, G. Grande, N. Brigante, L. Lesti, B and Somma, ...
  • Huang, J.-H. Yen, S.-C. and Lin, C.-P. (2008). Impedance characteristics ...
  • Ding, J. Gutmann, J.-1. Fan, B and Chen , H. ...
  • YMKN, Y. Jayasinghe, R. WPMM, A. Fonseka, M and Wettasinghe, ...
  • Headari, A. and Jalali-Yekta, H. (2008). Evaluation of the in ...
  • Hashemi Niya, S. M. Jafari, N. (2008). laboratory survey accuracy ...
  • Naulakha, D. Agrawal, M and Naulakha, N. (2015). D etermination ...
  • Kim, P. J. Kim, H. G. Cho, B. H. (2015). ...
  • Griffiths, B. Brown, J. Hyatt A and Linney, A. (1992). ...
  • POPESCU, A. (2010) . "Electronic Devices for Determining the Working ...
  • نمایش کامل مراجع