Assessment of flatness and Symmetry of intraoperative radiotherapy beam fieldsby radio chromic EBT-2 films

Publish Year: 1393
نوع سند: مقاله کنفرانسی
زبان: English
View: 497

نسخه کامل این Paper ارائه نشده است و در دسترس نمی باشد

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ICBCMED10_138

تاریخ نمایه سازی: 21 اردیبهشت 1397

Abstract:

Symmetry and flatness tests should be done by using suitable 3D motorized water phantom or appropriate radio chromic films and slab phantoms. The aim of this work is to check symmetry and flatness of Intraoperative Radiotherapy (IORT) fields by using EBT-2 films and beam profiles at 6,8,10 and 12 MeV. Methods and materials: Four pieces of EBT-2 films cut into 10×12.5 cm2 .Then films were scanned before and after irradiation. EBT-2 films put in reference condition (applicator 10 cm and 00 angel) and between vertical slab systems. Then, films irradiated in four energies 6, 8, 10, 12 MeV, separately. After irradiation, by using MATLAB software and selection of appropriate pixels can draw profiles Flatness aria is in 80% filed size. Flatness and symmetry were obtained by special formulas. For assessment of flatness, maximum and minimum dose must be achieved and for analyzing symmetry, dose in corresponding points in central axis in profile should be measured. Results: Flatness for 6, 8, 10,12MeV energies were measured 3.6, 3.2, 1.7 and 2.9, respectively. Also, symmetry measurement in order for above energies were obtained 1, 1, 0.9, and 0.9. Conclusion: absorbed dose variation inside the 80% of the field size (50% isodose) must be less than 3%. In our results, flatness was acceptable for all energies (just for 6, 8 MeV a little is bigger than 3%). Also, maximum absorbed dose between points equidistant from central beam axis, inside the 80% of field size must be less or equal 3% and our measurements of symmetries were equal or under 1%. Symmetry and flatness of IORT beam fields seems acceptable and reliable for all energies and it is appropriate for treatment condition.

Keywords:

symmetry , flatness , intraoperative radiotherapy , radio chromic EBT-2 films

Authors

Zahra Rahimzadeh Yekta

Sciences and Research Branch of Tehran, Islamic Azad University, Tehran, Iran

Seied rabi Mehdi Mahdavi

Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran

Hamidreza Mirzaie

Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Mohammad Esmaeil Akbari

Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran