CIVILICA We Respect the Science
Publisher of Iranian Journals and Conference Proceedings
Paper
title

ACCURATE CALCULATION of HORIZONTAL SHADING’S DEPTH in THE ORTHOPEDIC HOSPITAL in a COLD CLIMATE

Credit to Download: 1 | Page Numbers 7 | Abstract Views: 291
Year: 2015
COI code: ICOAC01_370
Paper Language: English

How to Download This Paper

For Downloading the Fulltext of CIVILICA papers please visit the orginal Persian Section of website.

Authors ACCURATE CALCULATION of HORIZONTAL SHADING’S DEPTH in THE ORTHOPEDIC HOSPITAL in a COLD CLIMATE

Mohammad Shahriyari - Young Researchers and Elite Club, Shahrekord Branch, Islamic Azad University, Shahrekord, Iran
  Amin Saberiyan Boroujeni - Department of Architecture, Boroujen Branch, Islamic azad university, Boroujen ,Iran

Abstract:

OBJECTIVE: To calculate the depth of the shading’s is known as a part of static cooling in the climatic design process of architecture and considering the position of windows, sometimes it can affect the pre-calculated architectural forms. This paper aims to examine the impact of the accuracy of the calculations on the depth of the shading’s. METHOD: In the process of hypothesis testing using the numerical solution of a horizontalshading on the southern side of Orthopedic Hospital in a cold climate, the importance of accuracy in calculating the depth of the shading’s will be examined, and the positive ornegative climatic effects will be stated. FINDINGS: Shading has been a basic principle in the designing method of great architects.In the calculation of the shading’s depth, given the step by step calculations, the more accurate the calculations, the more accurate the calculation of the shading’s depth would be. In the calculations, if the calculations’ accuracy is less than three decimal places, the value of theobtained depth of the shading would surprisingly be inaccurate up to 5 times, and consequently it may cause disruption in the static cooling process of the climatic designprocess. CONCLUSION: The accuracy of the calculations is seen as an integral part of engineeringexcellence. Sometimes, negligence of the calculations’ logic has adverse effects on final results. However, in a superficial view, it might be regarded ineffective or of little importance. Therefore, calculations must be carefully controlled in order that we may benefit operationalefficiency in the engineering, and avoid the adverse effects.

Keywords:

Climatic Design, shading’s depth, Static cooling, accurate calculation

Perma Link

https://www.civilica.com/Paper-ICOAC01-ICOAC01_370.html
COI code: ICOAC01_370

how to cite to this paper:

If you want to refer to this article in your research, you can easily use the following in the resources and references section:
Shahriyari, Mohammad & Amin Saberiyan Boroujeni, 2015, ACCURATE CALCULATION of HORIZONTAL SHADING’S DEPTH in THE ORTHOPEDIC HOSPITAL in a COLD CLIMATE, 6TH International Conference on Economics, Management and Engineering Sciences, بلژيك, مركز بين المللي ارتباطات دانشگاهي, https://www.civilica.com/Paper-ICOAC01-ICOAC01_370.htmlInside the text, wherever referred to or an achievement of this article is mentioned, after mentioning the article, inside the parental, the following specifications are written.
First Time: (Shahriyari, Mohammad & Amin Saberiyan Boroujeni, 2015)
Second and more: (Shahriyari & Saberiyan Boroujeni, 2015)
For a complete overview of how to citation please review the following CIVILICA Guide (Citation)

Research Info Management

Export Citation info of this paper to research management softwares

New Related Papers

Iran Scientific Advertisment Netword

Share this paper

WHAT IS COI?

COI is a national code dedicated to all Iranian Conference and Journal Papers. the COI of each paper can be verified online.