EFFECT OF THE CONCRETE STRENGTH ON THE CONCRETESTEEL BOND IN CONCRETE FILLED STEEL TUBES

Publish Year: 1391
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,292

This Paper With 9 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ICOPMAS10_177

تاریخ نمایه سازی: 4 اسفند 1391

Abstract:

In this study the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bondcarrying capacity. Four different mixes of concrete were used in preparing the specimens. The steel tubes were welded type with the nominal inside diameters of 3, 4, 6 and 8 inches. According to the test results, bond strength increases with reduction of the w/c ratio of concrete mixes. The high strength to normal concrete bond strength ratio increases with diameter of steel tubes. The bond strength decreases for higher diameters in both normal and high strength concrete specimens

Keywords:

composite structures , concrete filled steel tubes (CFST) , bond strength

Authors

Nahmat Khodaie

faculty member - Islamic Azad University-Khormouj Branch