Effect of Ambience Temperature and Electric Current Leakage on Vibration of High-Pressure Pump

Publish Year: 1398
نوع سند: مقاله ژورنالی
زبان: English
View: 350

This Paper With 10 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_SEE-4-4_011

تاریخ نمایه سازی: 6 اسفند 1398

Abstract:

In this paper, we make a brief overview of the maintenance procedures and condition monitoring methods. The WKL32 model high pressure pump made in Iran Pump Co, be evaluated by the vibration analysis and sound tests, based on the proactive maintenance procedure. We study the effect of electric current leakage which is made of using the pump chassis as the welding connection cable (NULL) and check the effect of the ambience temperature on the grease lubricant viscosity and on the corrosion of the pump’s bearings. Finally, we make appropriate cures according to the proactive maintenance procedure.

Authors

Behrang Sharafi

Department of Mechanical Engineering, University of Shahid Rajaee Teacher Training University, Tehran, Iran

Valiollah Panahizadeh Rahimloo

Department of Mechanical Engineering, University of Shahid Rajaee Teacher Training University, Tehran, Iran

Amir Refahi Oskouie

Department of Mechanical Engineering, University of Shahid Rajaee Teacher Training University, Tehran, Iran