Experimental investigation of the static load bearing capacity of a FRP-strengthened tubular T-joint under brace axial compressive loading

Credit to Download: 1 | Page Numbers 8 | Abstract Views: 16

How to Download This Paper

For Downloading the Fulltext of CIVILICA papers please visit the orginal Persian Section of website.

Authors Experimental investigation of the static load bearing capacity of a FRP-strengthened tubular T-joint under brace axial compressive loading

  Alireza Sadat Hosseini - PhD Student, University of Tehran
  Mohammad Reza Bahaari - Professor, University of Tehran;
Mohammad Lesani - Assistant Professor, Sadra University;

Abstract:

This paper presents the results of an experimental research program conducted on a FRP strengthened steel tubular T-joint made of Circular Hollow Sections. The specimen was reinforced by uni-directional glass fibers impregnated with vinyl ester resin and wrapped all around the intersection of the members and the adjacent areas. Axial compression in shape of displacement controlled non-linear static loading acting on the brace member and consequently on the chord face at the intersection was selected for the monotonic loading regime. The load–displacement was recorded during the experiments. Results of this study have been compared with a formerly conducted experiment on a FRP-strengthened tubular T-joint to evaluate how the joint geometry affects the FRP efficacy on the improvement of joint static capacity. Assessment of the relative studies confirms that the FRP wrapping has significant influence on the ultimate load capacity of the connections and can highly improve the connection behavior. In addition, it was found that joint’s geometry plays a significant role on the FRP effectiveness

Keywords:

Tubular connection, FRP-strengthening, Experimental specimen, Static load bearing capacity, Geometrical parameters.

Perma Link

https://www.civilica.com/Paper-SECM03-SECM03_154.html
COI code: SECM03_154

how to cite to this paper:

If you want to refer to this article in your research, you can easily use the following in the resources and references section:
Sadat Hosseini, Alireza; Mohammad Reza Bahaari & Mohammad Lesani, 2019, Experimental investigation of the static load bearing capacity of a FRP-strengthened tubular T-joint under brace axial compressive loading, rd International Conference on Applied Researches in Structural Engineering and Construction Management (secm2019), تهران, دانشگاه صنعتي شريف, https://www.civilica.com/Paper-SECM03-SECM03_154.htmlInside the text, wherever referred to or an achievement of this article is mentioned, after mentioning the article, inside the parental, the following specifications are written.
First Time: (Sadat Hosseini, Alireza; Mohammad Reza Bahaari & Mohammad Lesani, 2019)
Second and more: (Sadat Hosseini; Bahaari & Lesani, 2019)
For a complete overview of how to citation please review the following CIVILICA Guide (Citation)

Scientometrics

The University/Research Center Information:
Type: state university
Paper No.: 50880
in University Ranking and Scientometrics the Iranian universities and research centers are evaluated based on scientific papers.

Research Info Management

Export Citation info of this paper to research management softwares

New Related Papers

Iran Scientific Advertisment Netword

Share this paper

WHAT IS COI?

COI is a national code dedicated to all Iranian Conference and Journal Papers. the COI of each paper can be verified online.