GUIDELINES FOR SEISMIC EVALUATION OF MASONRY BUILDINGS IN IRAN
Publish Year: 1382
نوع سند: مقاله کنفرانسی
زبان: English
View: 2,421
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
SEE04_BS61
تاریخ نمایه سازی: 10 آبان 1384
Abstract:
In this paper guidelines are introduced for seismic evaluation of typical masonry buildings in Iran with the objective of directing the evaluating engineers to determine if there is any deficiency in the building that could pose a potentially serious risk to life safety. These guidelines deal with common deficiencies in six general areas consisting of building materials,structural systems, bearing walls, diaphragms, connections of structural elements, and nonstructural items. The common deficiencies in each area is identified based experiences from past earthquakes as those structural flaws which could lead to component failure and to partial or total collapse of the building.
Authors
A. VASSEGHI
Assistant Professor, IIEES, Tehran, I.R. Iran
M. R. MAHERI
Associate Professor, Shiraz University, Shiraz, I.R. Iran
M. MOTAMEDI
Faculty, Islamic Azad University -South Tehran, Tehran, I.R. Iran
F. ALEMI
PhD student, IIEES, Tehran, I.R. Iran