CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Application of graphene nanoplatelets silica composite, prepared based on sol-gel technology, as a novel sorbent in two microextraction techniques

عنوان مقاله: Application of graphene nanoplatelets silica composite, prepared based on sol-gel technology, as a novel sorbent in two microextraction techniques
شناسه ملی مقاله: NHSMED01_076
منتشر شده در اولین کنگره ملی نانو فناوری در علوم سلامت در سال 1397
مشخصات نویسندگان مقاله:

Mahmoud Heidari - Department of Occupational Health, School of Health, Guilan University of Medical Sciences, Rasht, Iran
Abdolrahman Bahrami , - Department of Occupational Health, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
Ali Reza Ghiasvand - Department of Chemistry, Faculty of Science, Lorestan University, Khoramabad, Iran
Farshid Ghorbani Shahna - Department of Occupational Health, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
Ali Reza Soltanian - Department of Biostatistics and Epidemiology, School of Health, Hamadan University of Medical Sciences, Hamadan, Iran
Seyed Ghavameddin Attari - Department of Occupational Hygiene Engineering, Boroujerd Branch, Islamic Azad University, Boroujerd, Lorestan, Iran.

خلاصه مقاله:
In this study the application of a novel nano-material composite was investigated in two microextraction techniques of solid phase microextraction and needle trap device in a variety of sampling conditions. The optimum sampling temperature and relative humidity were 10 °C and 20%, respectively for both techniques with two sorbent of graphene/silica composite and polydimethyl siloxane. The two microextraction techniques with the proposed sorbent showed recovery of 95.2% and 94.6% after 7 days. For needle trap device the optimums desorption time and temperature were 3 min at 290 °C and for SPME these measures were 1 and 1.5 min at 240-250 °C for the graphene/silica composite and polydimethyl siloxane, respectively. The relative standard division obtained in inter and intra-techniques comparative studies were 3.3-14.3% and 5.1-25.4% respectively. For four samplers the limit of detection ranged from 0.021-0.25 ng/mL and the limit of quantitation from 0.08-0.75 ng/mL. The results show that graphene/silica composite is an appropriate extraction media for both techniques. Combining an appropriate sorbent with microextraction techniques, and using these in conjunction with a sensitive analytical instrument can introduce a strong method for sampling and analysis of occupational and environmental pollutants in air

کلمات کلیدی:
Nano-platelets graphene; Sol-gel technology; Needle trap device; Solid phase microextraction; Carbon tetrachloride

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/964930/