Publisher of Iranian Journals and Conference Proceedings

Please waite ..
Publisher of Iranian Journals and Conference Proceedings
Login |Register |Help |عضویت کتابخانه ها
Paper
Title

Investigating the Treatment of Oil and Gas Produced Water Using a Spray Dryer on a Bench Scale

Year: 1399
COI: JR_IJOGST-9-1_002
Language: EnglishView: 264
This Paper With 17 Page And PDF Format Ready To Download

Buy and Download

با استفاده از پرداخت اینترنتی بسیار سریع و ساده می توانید اصل این Paper را که دارای 17 صفحه است به صورت فایل PDF در اختیار داشته باشید.
آدرس ایمیل خود را در کادر زیر وارد نمایید:

Authors

Mohammad Razaghiyan - Ph.D. Student, Chemical Engineering Department, Faculty of Engineering, Yasouj University, Yasouj, Iran
Mahmood Reza Rahimi - Associate Professor, Process Intensification Lab, Chemical Engineering Department, Faculty of Engineering, Yasouj University, Yasouj, Iran
Hajir Karimi - Associate Professor, Chemical Engineering Department, Faculty of Engineering, Yasouj University, Yasouj, Iran

Abstract:

The current work investigates the performance of a single-stage, bench-scale system using a spray dryer to treat produced water. The produced water is generated in three large reservoirs of Ahvaz, Maroon, and Mansouri fields, which have different compositions but the same high total dissolved solids (TDS) and total organic carbon (TOC). The results of this study indicate that the newly developed bench scale rig is able to reduce the amount of TDS in the water produced in Ahvaz, Maroon, and Mansouri reservoirs to 98.78, 98.65, and 98.90, and TOC decreases the three types of the produced water to zero. Investigating the effect of independent parameters on the performance of this system using response surface methodology shows that the most effective parameters affecting the efficiency of the produced water treatment system are the entering carrier gas temperature (TGIT), the flow rate of the produced water (QL), the carrier gas flow rate entering the spray dryer (QG), and the atomizer pore size (d). Additionally, the optimal conditions are obtained as follows: TGIT = 113.7 °C, QL = 20.8 cc/min, QG = 59.9 m3/hr., and d = 0.03 mm.

Keywords:

Paper COI Code

This Paper COI Code is JR_IJOGST-9-1_002. Also You can use the following address to link to this article. This link is permanent and is used as an article registration confirmation in the Civilica reference:

https://civilica.com/doc/1015935/

How to Cite to This Paper:

If you want to refer to this Paper in your research work, you can simply use the following phrase in the resources section:
Razaghiyan, Mohammad and Rahimi, Mahmood Reza and Karimi, Hajir,1399,Investigating the Treatment of Oil and Gas Produced Water Using a Spray Dryer on a Bench Scale,https://civilica.com/doc/1015935

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :

  • Andrade, V.T., Andrade, B.G., Costa, B.R.S., Pereira, O.A., and Dezotti, ...
  • Barrufet, M.A., Burnett, D.B., and Mareth, B., Modeling and Operation ...
  • Bazaria, B., Kumar, P., Food Bioscience Effect of Whey Protein ...
  • Boysen, J., Boysen, D., The Freeze-Thaw/Evaporation (FTE) Process for Produced ...
  • Boysen, J.E., J.A., Harju, B.S., Fosdick, M., Grisanti, A., Sorensen, ...
  • Burnett, D.B., Potential for Beneficial Use of Oil and Gas ...
  • Czeslaw Strumillo, T.K., Drying: Principles, Applications, and Design, CRC Press, ...
  • Doran, G.F., Carini, F.H., Fruth, D. a, Drago, J. a, ...
  • Doran, G.F., Williams, K.L., Drago, J.A., Huang, S.S., Leong, L.Y.C., ...
  • Erbay, Z., Icier, F., Optimization of Hot Air Drying of ...
  • Erbay, Z., Koca, N., Kaymak-ertekin, F., Ucuncu, M., Optimization of ...
  • Fakhru’l-Razi, A., Pendashteh, A., Abdullah, L.C., Biak, D.R.A., Madaeni, S.S., ...
  • Hamed, O.A., Evolutionary Developments of Thermal Desalination Plants in the ...
  • Holman, J.P., Experimental Methods for Engineers, Seventh Edition, McGraw Hill, ...
  • Igunnu, E.T., Chen, G.Z., Produced Water Treatment Technologies, p. 1–21, ...
  • Jamei, M., Reza, M., Nikou, K., Enhanced Removal of Pb ...
  • Khedr, G., Nanofiltration and Low Energy Reverse Osmosis for Advanced ...
  • Minier-Matar, J., Hussain, A., Janson, A., Wang, R., Fane, A.G., ...
  • Osipi, S.R., Secchi, A.R., Borges, C.P., Cost Assessment and Retro-techno-economic ...
  • Pentz, W.F., n.d., Cyclone Design Equations Formulas Calculator. ...
  • Piemonte, V., Prisciandaro, M., Mascis, L., Di Paola, L., Barba, ...
  • Raimundo, C., Martins, E., Caldas, A., Silveira, P., Simeão, M., ...
  • Riley, S.M., Ahoor, D.C., Oetjen, K., Cath, T.Y., Closed Circuit ...
  • Sanmartino, J.A., Khayet, M., García-Payo, M.C., Desalination by Membrane Distillation, ...
  • Sarker, M.H., Burnett, D.B., Siddiqui, M., Recovery of Fresh Water ...
  • Shaffer, D.L., Arias Chavez, L.H., Ben-Sasson, M., Romero-Vargas Castrillón, S., ...
  • Taylor, P., Erbay, Z., Koca, N., Energetic, Exergetic, and Exergoeconomic, ...
  • Téllez, D., Lom, H., Chargoy, P., Rosas, L., Mendoza, M., ...

Research Info Management

Certificate | Report | من نویسنده این مقاله هستم

اطلاعات استنادی این Paper را به نرم افزارهای مدیریت اطلاعات علمی و استنادی ارسال نمایید و در تحقیقات خود از آن استفاده نمایید.

Scientometrics

The specifications of the publisher center of this Paper are as follows:
Type of center: دانشگاه دولتی
Paper count: 3,524
In the scientometrics section of CIVILICA, you can see the scientific ranking of the Iranian academic and research centers based on the statistics of indexed articles.

Share this page

More information about COI

COI stands for "CIVILICA Object Identifier". COI is the unique code assigned to articles of Iranian conferences and journals when indexing on the CIVILICA citation database.

The COI is the national code of documents indexed in CIVILICA and is a unique and permanent code. it can always be cited and tracked and assumed as registration confirmation ID.

Support