The relationship between compressive strength and splitting tensile strength of HPFRCC

Publish Year: 1399
نوع سند: مقاله کنفرانسی
زبان: English
View: 355

This Paper With 13 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

CAUM03_164

تاریخ نمایه سازی: 16 آبان 1399

Abstract:

High-performance fiber-reinforced cementitious composites (HPFRCC), are specified by a stress-strain response in tension that shows multiple cracking and strain-hardening behavior. The aim of this experimental study is to investigate two main parameters in the structural design such as splitting tensile strength (fspt), and the compressive strength (fc) of HPFRCC. In this study, 18 mix proportion of HPFRCC were made and a total of 108 cylinder and cube specimens of HPFRCC at 7 and 28 days were tested then the relationship between splitting tensile strength and compressive strength of HPFRCC with 1% steel fibers was proposed, the prediction errors run below ±15%. The HPFRCC were mixed with the different type of aggregate shape and content, water-to-cement (w/c) ratio, silica fume, and amount of superplasticizer.

Keywords:

high -performance fiber-reinforced cement composite , compressive strength , splitting tensile strength , non-linear regression (NLR).

Authors

Mahdieh Sabbaghian

M.Sc, Faculty of Civil Engineering, Semnan University

ali kheyroddin

Professor, Faculty of Civil Engineering, Semnan University,