ASSESSMENT OF SITE EFFECTS AND SOIL-STRUCTURE RESONANCE IN ALGIERS CENTER

Publish Year: 1398
نوع سند: مقاله کنفرانسی
زبان: English
View: 144

متن کامل این Paper منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل Paper (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

SEE08_370

تاریخ نمایه سازی: 23 آبان 1399

Abstract:

The damage pattern in urban areas during an earthquake depends on the characteristics of the event and on the interaction between site response and vulnerability of the exposed structures (Gosar, 2012). Shear wave velocity Vs is one of the most important input parameter to characterize the dynamic properties of soil. Several geotechnical and geophysical methods are developed for estimates directly or indirectly the parameter Vs. The microtremor horizontal-to-vertical spectral ratio (HVSR) method has been widely used for site effect studies (Ohmachi et al., 1991; Field and Jacob, 1995; Bard, 1998). The application of microtremor measurements has been extended to identify the fundamental frequencies of buildings (Goar, 2010).The results of site response using microtremor measurements compared with geological and boreholes data for Algierscenter is one the main objective of this research work. The horizontal to vertical spectral ratio (HVSR) technique has been applied in order to assess the fundamental frequencies of the soil, beside the transversal and longitudinal frequencies of each selected building are also identified, in order to detect the potential risk of soil structure resonance. The geology of the study zone, Algiers region located Figure 1, is represented by metamorphic rocks surrounded by Mio-Plio Quaternary sedimentary deposits (Saadallah, 1981). Nearly 33 geotechnical boreholes have been drilled to different depths in the region study. The resonance frequency (H/V) values calculated using the Nakamura technique seismograph instruments recorded on 24 sites (Figure 1). In SPT test case, the soil identification is based on soil sampling, and the blow count N-value is obtained. Many correlations between Vs and penetration resistance have been developed for different soils. The investigations carried out during the realization of the subway gives the range (5-60) of NSPT values for 12 m of depth means that the soil is hard to very hard near the surface (GMAC,1984). The corresponding fundamentally frequency is in the range 15-45 Hz, that confirmed the observation, in some places rock outcrop is also visual identified. At the periphery of the layout subway, the borehole details were collected to a depth of about 30 m (JICA, 2006). The results show that the values frequencies are closed between the range 0.2 - 16 Hz.

Authors

Yamina AIT-MEZIANE

Ph.D., National Earthquake Engineering Research Center, Algiers, Algeria

Rania SOUICI

Ph.D. Student, USTHB, FGC, LBE, University of Sciences & Technology Houari Boumediene, Algiers, Algeria

Djilali BOUZIANE

Assistant Researcher, National Earthquake Engineering Research Center, Algiers, Algeria

Nabila GUESSOUM

Ph.D. Student, National Earthquake Engineering Research Center, Algiers, Algeria