EVALUATION OF SEISMIC RESPONSE OFTALL BUILDINGS WITH FRAMED TUBESKELETONS IN HIGH SEISMIC AREAS

Publish Year: 1394
نوع سند: مقاله کنفرانسی
زبان: English
View: 206

This Paper With 8 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

SEE07_333

تاریخ نمایه سازی: 29 آذر 1399

Abstract:

In this research, the performance abilities associated with tube type lateral load resistant framed systems are studied in order to assess the seismic response parameters of steel tall buildings subjected to both far and near-field earthquake records. For this purpose, four 30 story structural models with framed tube based skeletons were selected and designed. The plans of models are squared shape. The structural response parameters have been computed and obtained by conducting a number of non-linear dynamic time history analyses. The structural models have been designed according to the Iranian seismic code 2800(third edition). Findings from this study reveal that, mean maximum demands and the dispersion in the peak values were extremely higher for near-fault records than far-fault motions. The maximum story drift for the studiedmodels was determined and compared with the “life safety” and “collapse prevention” performance limits, as recommended by FEMA 356.

Authors

Masoud AZHDARIFAR

MSc Student, Kharazmi University, Faculty of Engineering, Tehran, Iran

Afshin MESHKAT-DINI

Assistant Professor, Kharazmi University, Tehran, Iran

Abdol-Reza SARVGHAD MOGHADAM

Associate Professor, Int. Institute of Earthquake Engineering and Seismology, Tehran, Iran