Evaluation of Marginal Fit of Three Different Interim Restoration Materials - An In-vitro Study

Publish Year: 1399
نوع سند: مقاله ژورنالی
زبان: English
View: 222

This Paper With 10 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JDMT-9-3_008

تاریخ نمایه سازی: 19 دی 1399

Abstract:

Introduction: The aim of this experimental in-vitro study was to evaluate and compare marginal accuracy of interim restorations made with three chemically different  interim materials one hour after fabrication and at one week interval. Methods: Twenty samples from each group with a total of sixty were fabricated on a customized metal die. The three test groups were as below; Group A - Protemp TM 4 (3M ESPE AG Dental Products, Germany), a bis-acrylic based self-cure temporary material; Group B - Revotek LCTM (GC Dental Products Corp., Japan), a urethane dimethacrylate based light cure temporary material and Group C - Tuff-Temp™ Plus (Pulpdent Corporation, U.S.A), a rubberized-urethane based dual cure temporary material. All samples were stored in artificial saliva and evaluated for marginal discrepancy using a stereomicroscope, one hour and one week after fabrication. Statistical analysis was done using one way ANOVA test and Tukeys Post-hoc tests. Results: Statistical significant difference existed between three groups after one hour (p <0.001) and after one week (p <0.001), Tuff-Temp™ Plus showed the least marginal discrepancy (at one hour =192.3± 0.75µm; at one week = 242.69 ± 5.64µm), while Revotek LCTM (at one hour = 232.52± 0.48µm; at one week = 293.68 ± 3.75µm) had the highest discrepancy. Conclusions: Tuff-Temp™ Plus showed higher marginal accuracy followed Protemp TM 4 and Revotek LCTM at one hour and one week interval.

Authors

Ahmed Patel

Dr. Ahmed Ayub Patel MDS, Department of Prosthodontics M. A. Rangoonwala College of Dental Sciences and Research Centre Pune +۹۱۹۵۱۸۷۸۸۳۰۵

Ramandeep Dugal

Dr. Ramandeep Dugal MDS, HOD and Professor Department of Prosthodontics M. A. Rangoonwala College of Dental SCiences and Research Centre Pune

Pallavi Madanshetty

Diploma Dental Materials Rural Dental College, Loni, India

Aamir Godil

Dr. Aamir Zahid Godil MDS, Senior Lecturer Department of Prosthodontics M. A. Rangoonwala College of Dental Sciences and Research Centre Pune +۹۱۸۱۶۰۶۶۶۵۷۶ +۹۱۹۰۴۹۲۱۰۵۴۹

Arshi Kazi

Department of Prosthodontics, Post-graduate Student, M. A. Rangoonwala of Dental Sciences and Research Centre, Pune, Maharashtra, India

Ajinkya Kirad

Dr. Ajinkya Sanjiv Kirad MDS, Department of Prosthodontics M. A. Rangoonwala College of Dental Sciences and Research Centre Pune

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Gratton DG, Aquilino SA. Interim restorations. Dent Clin N Am. ...
  • Balkenhol M, Knapp M, Ferger P, Heun U, Wo¨ stmann ...
  • Abouelatta O, El-Bediwi A, Sakrana A, Jiang X, Blunt L. ...
  • Robinson FB, Hovijitra S. Marginal fit of direct temporary crowns. ...
  • Michalakis K, Pissiotis A, Hirayama H, Kang K, Kafantaris N. ...
  • Ehrenberg D, Weiner G, Weiner S. Long-term effects of storage ...
  • Ehrenberg D, Weiner S. Changes in marginal gap size of ...
  •  Strassler HE. In-office provisional restorative materials for fixed prosthodontics: part ...
  • Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE. ...
  • Rosenstiel S, Land M, Fujimoto J. Contemporary fixed prosthodontics.4th ed. ...
  • Nejatidanesh F, Lotfi HR, Savabi O. Marginal accuracy of interim ...
  • Ireland MF, Dixon DL, Breeding LC, Ramp MH. In vitro ...
  • Young HM, Smith CT, Morton D. Comparative in vitro evaluation ...
  • Haselton DR, Diaz-Arnold AM, Vargas MA. Flexural strength of interim ...
  • Lang R, Rosentritt M, Behr M, Handel G. Fracture resistance ...
  • Grajower R, Shaharbani S, Kaufman E. Temperature rise in pulp ...
  • Wang RL, Moore BK, Goodacre CJ, Swartz ML, Andres CJ. ...
  • Barghi N, Simmons EW Jr. The Marginal Integrity of the ...
  • Venz S, Dickens B. NIR-spectroscopic investigation of water sorption characteristics ...
  • Braden M, Davy KW. Water sorption characteristics of some unfilled ...
  • Burns DR, Beck DA, Nelson SK. A review of selected ...
  • Ana M, Arnold D, Dunne JT, Jones AH. Microhardness of ...
  • Michele F, Donna L, Dixon, Breeding LC, Ramp MH. In- ...
  • Monday IJ, Blais D. Marginal adaptation of provisional acrylic resin ...
  • Moulding MB, Loney RW. Marginal accuracy of provisional restoration fabricated ...
  • Tjan AH, Castelnuovo J, Shiostu G. Marginal fidelity of crowns ...
  • Ferracane JL. Hygroscopic and hydrolytic effects in dental polymer networks. ...
  • Nawafleh,Mack evans,Mackay. Accuracy and Reliability of Methods to Measure Marginal ...
  • Al Rifaiy MQ. Evaluation of vertical marginal adaptation of provisional ...
  • Verma R, Nagpal A, Verma PR, Chadda AS. Marginal Accuracy ...
  • Koumjian JH, Holmes JB. Marginal accuracy of provisional restorative material. ...
  • Gudapati S, Jagadish HG, Alla RK, Sajjan S, Ramya K, ...
  • Khosravanifard B, Nemati-Anaraki S, Nili S, Rakhshan V. Assessing the ...
  • Nivedita S, Prithviraj DR. A comparative study to evaluate the ...
  • Givens EJ, Neiva G, Yaman P, Dennison JB. Marginal adaptation ...
  • Nejatidanesh F, Lotfi HR, Savabi O. Marginal accuracy of interim ...
  • Rastogi A, Kamble V. Comparative analysis of the clinical techniques ...
  • Kim SH, Watts DC. Polymerization shrinkage-strain kinetics oftemporary crown and ...
  • Jafarzadeh-Kashi TS, Mirzaii M, Erfan M, Fazel A, Eskandarion V, ...
  • Wassell RW, George GS, Ingledew RP, Steele JG. Crowns and ...
  • نمایش کامل مراجع