PERFORMANCE OF SAFE ROOM UNDER JACKARCH ROOF COLLAPSE
عنوان مقاله: PERFORMANCE OF SAFE ROOM UNDER JACKARCH ROOF COLLAPSE
شناسه ملی مقاله: SEE06_337
منتشر شده در ششمین کنفرانس بین المللی زلزله شناسی و مهندسی زلزله در سال 1390
شناسه ملی مقاله: SEE06_337
منتشر شده در ششمین کنفرانس بین المللی زلزله شناسی و مهندسی زلزله در سال 1390
مشخصات نویسندگان مقاله:
M Yekrangnia - Ph.D. Candidate, Sharif University of Technology
A Mahdizadeh Sari - Head of Seismic Rehabilitation Schools Office
خلاصه مقاله:
M Yekrangnia - Ph.D. Candidate, Sharif University of Technology
A Mahdizadeh Sari - Head of Seismic Rehabilitation Schools Office
In this article the performance of a proposed safe room under roof gravitational loading is studied by finite element analysis. The aim of this article is about the sufficiency of the proposed system as an option in retrofitting the averaged size classrooms with jack-arch roofs. Different configurations are studied in order to determine the optimum configuration. In these analyses, it is assumed that the masonry walls are totally destructed and hence, the safe room is the only structural component, capable of bearing the roof gravity loads.
کلمات کلیدی: Safe Room, Gravitational Loading, Jack-Arch Roof, Buckling, Composite Section
صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/115273/