CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Evaluating the Changes in Distance Stereopsis Caused by Induced Heterophoria in Normal Persons by Three Needle Test

عنوان مقاله: Evaluating the Changes in Distance Stereopsis Caused by Induced Heterophoria in Normal Persons by Three Needle Test
شناسه ملی مقاله: JR_ZUMS-21-84_005
منتشر شده در در سال 1391
مشخصات نویسندگان مقاله:

اکرم احیائی - Dept. of Optometry, School of Para Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
جواد هرویان - Dept. of Optometry, School of Para Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
حبیب ا... اسماعیلی - Dept. of Social Medicine, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran

خلاصه مقاله:
Backgrounds and Objective: Stereoacuity is due to a relative difference between images because of retinal disparity. Measurment of stereoacuity is important for diagnosis and treatment of binocular anomalies and noerological problems. The aim of this study was to determine the effect of induced heterophoria by base-out and base-in prisms on distance stereopsis by the Three Needle Test. Materials and Methods: This descriptive-analytical study was performed on ۵۰ normal persons in the Optometry Clinic at Mashhad University of Medical Sciences during ۲۰۱۲. After primary examination, distance heterophoria was determined by cover test and prism bar. All subjects were orthophoric and had a maximum corrected vision of ۶۶. Esophoria and exophoria were induced using prisms dioptres of ۲, ۴, ۶, and ۸ base-in and base-out. The stereopsis was then determined by the Three Needle test in distance observation of ۶ meters in orthophoric, esophoric, and exophoric states. Data were analyzed using SPSS software. Results: Comparison between mean stereopsis in orthophoric and induced esophoric states was only statistically significant in ۴ prism dioptres (P=۰.۰۰۶). However, comparison of mean stereopsis in orthophoric with induced exophoric states indicated statistically significant differences for all values of ۲, ۴, ۶, and ۸ prism dioptres (P=۰.۰۰۹, P<۰.۰۰۰۱, P<۰.۰۰۰۱and P<۰.۰۰۰۱ respectively). Comparison between the mean stereopsis for the induced esophoric and exophoric states indicated statistically significant differences for ۲, ۴, and ۶ prism dioptres. Conclusion: There is a reduction of stereopsis with induced heterophoria. Stereopsis seems to decrease more with induced esophoria than exophoria.

کلمات کلیدی:
Keywords: Heterophoria, Distance stereopsis, Three needle test

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1191422/