CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Is the ۲۸-Day Rule Safe for Use in Abdominal Radiography?

عنوان مقاله: Is the ۲۸-Day Rule Safe for Use in Abdominal Radiography?
شناسه ملی مقاله: JR_IJMP-18-3_006
منتشر شده در در سال 1400
مشخصات نویسندگان مقاله:

Soo-Foon Moey - Department Of Diagnostic Imaging And Radiotherapy, Kulliyyah Of Allied Health Sciences, International Islamic University Malaysia, Jln Sultan Ahmad Shah, Bandar Indera Mahkota, ۲۵۲۰۰ Kuantan, Pahang, Malaysia
Norfariha Che Mohamed - Department Of Diagnostic Imaging And Radiotherapy, Kulliyyah Of Allied Health Sciences, International Islamic University Malaysia, Jln Sultan Ahmad Shah, Bandar Indera Mahkota, ۲۵۲۰۰ Kuantan, Pahang, Malaysia
Nursyahirah Saidin - Department Of Diagnostic Imaging And Radiotherapy, Kulliyyah Of Allied Health Sciences, International Islamic University Malaysia, Jln Sultan Ahmad Shah, Bandar Indera Mahkota, ۲۵۲۰۰ Kuantan, Pahang, Malaysia

خلاصه مقاله:
Introduction: The ۲۸-day rule is utilized as a precautionary measure for irradiating the fetus at an early stage of conception for abdominal and pelvic radiography. There is a probability of the women being pregnant if the ۲۸-day rule is applied for this examination and thus irradiating the conceptus. It is difficult to convince people that low radiation doses during early pregnancy will not cause any harm to the conceptus. As such this study was to ascertain whether the ۲۸-day rule can be used safely for abdominal radiography in women of reproductive age. Material and Methods: The experimental study was conducted at the Radiography Laboratory, International Islamic University Malaysia, Kuantan using an anthropomorphic PBU-۵۰ phantom. The entrance surface dose (ESD), organ dose and effective dose (ED) were estimated using CALDose_X ۵.۰ software, based on the exposure parameters and tube output of the x-ray unit. Results: The mean ESD for AP abdominal radiographic examination of ۳.۱۶۲ mGy is within that recommended by radiation protection regulatory bodies. Additionally, the mean organ dose of ۰.۴۶۸ mGy is lower than the threshold value of ۱۰۰ mSv for the “all-or-none” phenomenon to happen. Further, the mean ED of ۰.۷۳ mSv is within the recommendation of the International Atomic Energy Agency (IAEA) and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Conclusion: This study indicated that the ۲۸-day rule is safe to be used for abdominal radiography for a woman of reproductive age.

کلمات کلیدی:
Abdominal radiography, Radiation Protection, Radiation Dosage

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1225370/