Diagnostic Efficacy of Technetium-۹۹m-Sestamibi Scintimammography in Comparison with Mammography toDetect Breast Lesions: A Systematic Review

عنوان مقاله: Diagnostic Efficacy of Technetium-۹۹m-Sestamibi Scintimammography in Comparison with Mammography toDetect Breast Lesions: A Systematic Review
شناسه ملی مقاله: JR_ARCHB-5-3_001
منتشر شده در شماره 3 دوره 5 فصل August در سال 1397
مشخصات نویسندگان مقاله:

Sahel Heydarheydari - Department of Medical Physics, Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran
Seyed Masoud Rezaeijo - Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Mohsen Cheki - Department of Radiologic Technology, Faculty of Paramedicine, Ahvaz Jundishapur University of Medical Sciences,Ahvaz, Iran
Ehsan Khodamoradi - Department of Radiology and Nuclear Medicine, Paramedical School, Kermanshah University of Medical Sciences,Kermanshah, Iran
Karim Khoshgard - Department of Medical Physics, Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran

خلاصه مقاله:
Background: To systematically review the performance of scintimammographycompared with mammography in detecting breast lesions.Methods: A literature search was performed in PubMed and ScienceDirectdatabases with “scintimammography AND breast lesions,” “mammography ANDbreast lesions,” “diagnostic value,” and “accuracy” as keywords to identify allrelated studies published in English from January ۱, ۲۰۰۰, to August ۱, ۲۰۱۷.Twenty-five studies, with a total of ۴۰۹۴ patients with clinically suspicious breastlesions, were included in the final analysis to assess the sensitivity, specificity,positive predictive value (PPV), and negative predictive value (NPV) ofscintimammography vs. mammography in detecting breast lesions.Results: The sensitivity and specificity of mammography were ۷۵.۸۲ ± ۱۰.۵۳(۹۵% confidence interval [CI], ۵۰-۸۴) and ۵۹.۵۸ ± ۲۲.۷۹ (۹۵% CI, ۲۰-۹۱.۴),respectively. The PPV and NPV of mammography were ۷۵.۶۰ ± ۲.۲۱ (۹۵% CI, ۴۲-۹۳) and ۶۱.۶۲ ± ۱.۶۷ (۹۵% CI, ۳۹.۱-۸۶), respectively. The sensitivity ofscintimammography was ۸۶.۶۴ ± ۸.۸۴ (۹۵% CI, ۵۸.۳-۱۰۰), and the specificity was۸۳.۴۲ ± ۱۰.۷۴ (۹۵% CI, ۶۰-۱۰۰). The PPV and NPV of scintimammography were۸۲.۱۰ ± ۱۱.۶۵ (۹۵% CI, ۵۸-۹۸.۳۰) and ۸۱.۰۲ ± ۱۷.۰۰ (۹۵% CI, ۴۵-۱۰۰), respectively.Conclusions: Although mammography has a high sensitivity in theexamination of older patients with fatty breast tissue, it is less reliable in detectingbreast lesions in young and premenopausal patients with dense breasts. Diagnosticaccuracy of scintimammography, as a functional imaging modality, is not affectedby breast density, contrary to mammography. Therefore, scintimammography canimprove the specificity of mammography.

کلمات کلیدی:
Technetium-۹۹m-sestamibi, scintimammography, mammography, breast Lesions