CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Modeling of Two Pressure Steam Turbine and Governor System in MAPNA Combined Cycle Power Plants

عنوان مقاله: Modeling of Two Pressure Steam Turbine and Governor System in MAPNA Combined Cycle Power Plants
شناسه ملی مقاله: ISME29_155
منتشر شده در بیست و نهمین همایش سالانه بین المللی انجمن مهندسان مکانیک ایران و هشتمین همایش صنعت نیروگاه های حرارتی در سال 1400
مشخصات نویسندگان مقاله:

Nasrollah Firouzi - Eng.Head of Turbine Control and Protection, MAPNA Electrical&Control Co.(MECO), Karaj, Iran
Behrouz Karjalian - Turbine Control and Protection Expert, MAPNA Electrical&Control Co.(MECO), Karaj, Iran
Mehdi Maleki - Turbine Control and Protection Expert, MAPNA Electrical&Control Co.(MECO), Karaj, Iran
Mehdi Hassani Keleshtary - Turbine Control and Protection Expert, MAPNA Electrical&Control Co.(MECO), Karaj, Iran

خلاصه مقاله:
In this paper, we have proposed a dynamic model for two stages HP-LP۱ steam turbine and governor control system, which is used in typical MAPNA combined cycle power plants. This model is based on real process data extracted from power plant DCS۲ and governor control system. Power plant real input data have been integrated in a MATLAB spread sheet and applied to the model. Then the model outputs are obtained and compared to the real process data.In a combined cycle power plant, like what we have evaluated in this paper, main input is the electrical power of gas turbines-generators connected to HRSG۳s and the main output is electrical power of steam turbine-generator, respectively.However, there are some peripheral parameters like steam pressure upstream turbine, or governor control valves position, that could be useful to realize the steam turbine and governor system performance. In the proposed model, we have used not only the main input/output parameters, but also peripheral parameters to show the accuracy and conformity of model outputs with actual process values.Comparing simulated model output parameters and power plant real data, indicates high accuracy and small error which is shown in this paper through comparative curves and accumulative error calculations.

کلمات کلیدی:
Power Plant, STG, Governor, DCS, HRSG