Optimization of Energy Window and Collimator for Y-۹۰ Bremsstrahlung SPECT imaging: A Monte Carlo Simulation Study

عنوان مقاله: Optimization of Energy Window and Collimator for Y-۹۰ Bremsstrahlung SPECT imaging: A Monte Carlo Simulation Study
شناسه ملی مقاله: JR_IJMP-18-4_005
منتشر شده در در سال 1400
مشخصات نویسندگان مقاله:

Hicham Asmi - Department of Physics, LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco
Farida Bentayeb - Department of Physics,LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco
Youssef Bouzekraoui - Department of Physics,LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco
Faustino Bonutti - Academic Hospital of Udine, Department of Medical Physics, Udine, Italy
sanae douama - Department of Physics,LPHE, Modeling and Simulations, Faculty of Science,Mohammed V University, Rabat, Morocco

خلاصه مقاله:
Introduction: In yttrium-۹۰ imaging, image quality is highly dependent on the selection of energy window and collimator design becausetheY-۹۰ bremsstrahlung photons have a continuous and broad energy distribution. The current study aimed to optimize the bremsstrahlung energy window setting and collimator for the improvement of both resolution and sensitivity. Material and Methods: In the present study, simulation of medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate Siemens Medical System Symbia. The SIMIND was utilized to generate the Y-۹۰ bremsstrahlung single-photon emission computed tomography (SPECT) projection of the point source. Six energy windows settings and two collimators denoting medium energy and high energy were used in order to assess the effect of the energy window on the resolution. Results: The experimental measurements and simulation results showed a similar pattern in the point spread functions with the energy window. The simulation data indicated that the geometric component reached ۷۳%for the energy window within the range of۵۱-۱۲۰keVusingthe high-energy (HE) collimator. In addition, the obtained results showed that the full width at half maximum (FWHM) and full width at tenth maximum (FWTM)(FWHM=۷mm and FWTM=۳۵mm)were higher in this window in comparison to those reported for other windows. Conclusion: According to the obtained results of the present study, the optimal energy window for Y-۹۰ bremsstrahlung SPECT imaging was within the range of ۵۱-۱۲۰ keV. The obtained optimal energy window and optimal HE collimator had the potential to improve the image resolution and sensitivity of Y-۹۰ SPECT images

کلمات کلیدی:
Y, ۹۰ SPECT imaging Monte Carlo