SEISMIC EVALUATION OF A TALL CONCRETE BUILDING IN IRAN

Publish Year: 1378
نوع سند: مقاله کنفرانسی
زبان: English
View: 92

This Paper With 8 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

SEE03_059

تاریخ نمایه سازی: 20 مهر 1400

Abstract:

Seismic behavior of a ۶۰-story tubular concrete building with regular plan is evaluated. Through this, some parameters such as: P-A effects, infill masonry panels, and torsional effects are inspected separately. For evaluating the ductility reduction factor, inelastic behavior of the structure is also investigated. ETABS software (ver. ۶.۱۳) and DRAIN-۲D program were utilized for analyzing the linear and non-linear response of the structure, respectively. CONKER Software (ver. ۶.۱۳) was also used for the design of the ۶۰-story concrete building. By observing the results of the investigation, it's evident that the new version of BHRC-۲۸۰۰, Iranian Seismic Code, is upgraded thoughtfully because of the close and acceptable results of the inelastic response with those that are estimated in the Code.