A New Continuous Flow Injection Analysis Method Coupled with NAG-ADF-۳۰۰-۲ Analyzer for Promethazine-HCl by Cadmium Iodide as a Precipitating Reagent
Publish place: Chemical Methodologies، Vol: 5، Issue: 6
Publish Year: 1400
نوع سند: مقاله ژورنالی
زبان: English
View: 141
This Paper With 15 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_CHM-5-6_006
تاریخ نمایه سازی: 1 آبان 1400
Abstract:
A highly accurate, simple, sensitive turbidimetric method was introduced for the determination of promethazine-HCl using a homemade NAG-ADF-۳۰۰-۲ system with continuous flow injection analysis system. This method is based on reaction between promethazine-HCl and cadmium iodide (CdI۲) in the presence of ammonium acetate to obtain a white precipitate for the ion-pair complex. Turbidity was measured via the attenuation of incident light by precipitated at ۰-۱۸۰°. Optimum parameters were studied to increase the sensitivity for newly developed methodology of promethazine-HCl- cadmium iodide system. The linear dynamic range for the instrument response vs. concentration of promethazine-HCL- was ۰.۲۵-۲۵ mmol. L-۱ for cell A and ۰.۱-۲۰ mmol.L-۱ for cell B, and limit of quantitative (S/N=۱۰) ۳۶۰.۵۵۷۴ µg /sample for cell A and ۲۷۵.۵۸۳۰ µg /sample for cell B respectively with correlation coefficient (r) ۰.۹۹۶۱ for cell no. ۱ (cell A) and ۰.۹۹۶۶ for cell no.۲ (cell B); RSD % was lower than ۰.۶%. A comparison was made between the newly developed method with UV-Spectrophotometric and turbidimetric method as a classical method by using the standard addition method via the use of t-test at ۹۵% confidence level. In addition, F-test was utilized to predict which of the methods was more precise than other method. The comparison of data revealed that long distance chasing photometer (NAG-ADF-۳۰۰-۲) is the choice with excellent extended detection, wide application and more sensitivity.
Keywords:
Authors
Ghadah F. Hussein
Department of chemistry, College of Science, University of Baghdad, Baghdad, Iraq
Nagham S. Turkey
Department of chemistry, College of Science, University of Baghdad, Baghdad, Iraq
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :