Dosimetric Study in Tomotherapy Based on AAPM TG ۱۱۹ Structures: A Longitudinal Moving Phantom Case
Publish place: Iranian Journal of Medical Physics، Vol: 18، Issue: 5
Publish Year: 1400
نوع سند: مقاله ژورنالی
زبان: English
View: 155
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-18-5_005
تاریخ نمایه سازی: 1 آبان 1400
Abstract:
Introduction: Tomotherapy beam delivery is in the helical form. Therefore, the dose distribution will be more complex while target is moving. In this study, we sought to evaluate the dosimetric impact due to longitudinal motion in the phantom of a tomotherapy machine. Material and Methods: Cheese and Delta۴ phantom+ were placed on a respiratory motion platform. They moved in longitudinal directions at the amplitudes of ۲, ۴, ۶, ۸, and ۱۰ mm. The period of that movement was ۴ and ۶ s with the field widths of ۲۵ and ۵۰ mm, respectively. The C-shaped complex target was modified according to the American Association of Physicists in Medicine (AAPM) Task Group (TG) ۱۱۹. The planning verifications were evaluated through point dose, gamma index value, and dose-volume histogram (DVH).Results: Discrepancy of the dose measurements ranged from -۱.۲۵۴ to -۱۴.۴۲۱%. The range of gamma index value was ۶۱.۲ ±۱.۲۳% to ۱۰۰±۰.۰۰. The DVH evaluation showed that the homogeneity index (HI) and the minimum dose to receive by ۹۵% (D۹۵%) of the target structure were ۰.۲۴۷ to ۰.۳۸۹ and -۰.۰۶۱ to -۰.۲۷۱ Gy, respectively. The maximum dose (DMax) of the organ at risk (OAR) structure was ۰.۰۸۲ to ۰.۳۲۷ Gy.Conclusion: The motion could induce dose discrepancies in tomotherapy dose distribution. The selection of the jaw field width in tomotherapy is crucial for intensity-modulated radiotherapy (IMRT) techniques with moving targets. For larger field widths, the dose discrepancy between the planned and measured doses exhibited an excellent result for gamma index and dose coverage.
Keywords:
Authors
Nuruddin Nasution
Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, West Java, ۱۶۴۲۴, Indonesia Department of Radiotherapy, Cipto Mangunkusumo General Hospital, Jakarta, ۱۰۴۳۰, Indonesia
Wahyu Wibowo
Department of Radiotherapy, Cipto Mangunkusumo General Hospital, Jakarta, ۱۰۴۳۰, Indonesia
Adi Teguh Purnomo
Transmedik Indonesia, Jakarta, ۱۰۴۱۰, Indonesia
Supriyanto Pawiro
Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, West Java, ۱۶۴۲۴, Indonesia
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :