CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Evaluation of Coating Stability, Surface Characteristics and Biocompatibility of Nano Particle Coated Stainless Steel, Nickel-Titanium and Beta-Titanium Orthodontic Arch Wires in Comparison with Uncoated Wires: An In-Vitro Study

عنوان مقاله: Evaluation of Coating Stability, Surface Characteristics and Biocompatibility of Nano Particle Coated Stainless Steel, Nickel-Titanium and Beta-Titanium Orthodontic Arch Wires in Comparison with Uncoated Wires: An In-Vitro Study
شناسه ملی مقاله: JR_ORTHO-14-1_007
منتشر شده در در سال 1398
مشخصات نویسندگان مقاله:

Vasim Pinchani - Department of Orthodontics and Dentofacial Orthopaedics, M.A.Rangoonwala College of Dental Sciences and Research Centre, Pune, Maharashtra, India
Ajit J Kalia - Department of Orthodontics and Dentofacial Orthopaedics, M.A.Rangoonwala College of Dental Sciences and Research Centre, Pune, Maharashtra, India
Kannan Sharif - Department of Orthodontics and Dentofacial Orthopaedics, M.A.Rangoonwala College of Dental Sciences and Research Centre, Pune, Maharashtra, India
Salil Nene - Department of Orthodontics and Dentofacial Orthopaedics, M.A.Rangoonwala College of Dental Sciences and Research Centre, Pune, Maharashtra, India
Nasim Mirdehghan - Department of Orthodontics and Dentofacial Orthopaedics, M.A.Rangoonwala College of Dental Sciences and Research Centre, Pune, Maharashtra, India
Khadija M Dalvi - Department of Orthodontics and Dentofacial Orthopaedics, M.A.Rangoonwala College of Dental Sciences and Research Centre, Pune, Maharashtra, India

خلاصه مقاله:
Background Friction plays a major role during tooth movement as it takes up to ۶۰% of the applied force, hence reducing the force available for tooth movement. Coating the surface of orthodontic wires by various techniques is being developed to improve their mechanical and biological properties. Objectives To evaluate the characteristics of nano particle coated and uncoated stainless steel, nickel-titanium, and beta-titanium wires for (۱) coating stability, (۲) surface characteristics and (۳) biocompatibility after ۲۱ days of exposure to artificial saliva. Methods Six types of wires were tested for coating stability, surface characteristics before and after exposure to artificial saliva using scanning electron microscope and the artificial saliva was tested for leaching of ions by inductively coupled plasma optical emission spectrometer. Results Coating thickness was reduced in each group after exposure to artificial saliva which was statistically significant. Significant changes in surface morphology such as delamination and irregularity of the coating was noted. Coated NiTi wires showed lesser leaching of ions when compared with uncoated NiTi wires but the difference was not statistically significant. Conclusions Coating delamination and irregularities were seen in many areas. The highest concentration of ions leached among all the groups were of iron, followed by silica.

کلمات کلیدی:
Coated Archwires, SEM, Nano particles, Coating Stability, Surface roughness

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1303166/