Evaluation of Different Glazing Materials, Strategies, and Configurations in Flat Plate Collectors Using Glass and Acrylic Covers: An Experimental Assessment

Publish Year: 1400
نوع سند: مقاله ژورنالی
زبان: English
View: 160

This Paper With 10 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IJEE-12-4_003

تاریخ نمایه سازی: 16 آبان 1400

Abstract:

Glass plates have been commonly used as collectors’ covers due to technical feasibility, high transmissivity in shortwave solar irradiation, and low transmissivity in long-wavelengths. However, they are vulnerable to stones and hail. Plastic plates have high transmissivity in shortwaves but also have transmission bands in the middle of the thermal radiation spectrum. The current study represents an experimental assessment of different covering strategies, including single acrylic-cover, single glass-cover, double glass- acrylic cover, and double glass-cover. Two solar air heaters (SAHs) prototypes were constructed for this study. The acquired experimental runs illustrated that the single glass-covered SAH represents higher thermal performance than the single acrylic-covered SAH due to the lower transmissivity of glass plates in long wavelengths. The double-covered SAHs have higher performance than the similar single-covered SAHs. In the double-covered SAHs, the convective-radiant heat loss is reduced. However, increasing the cover number improves the radiant resistance to solar irradiation and reduces the collector performance when solar irradiation is insufficient and the absorber temperature is low, especially at the beginning of daytime hours. The SAH using a double-glass cover is preferable; however, the heat dynamics of the double glass- acrylic-covered SAH are so close to the double glass-covered one, and the acrylic plate is more resistant to harsh ambient conditions.

Authors

M. Ameri

Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

H. Farzan

Department of Mechanical Engineering, Higher Education Complex of Bam, Bam, Iran

M. Nobari

Department of Mechanical Engineering, Shahid Bahonar University of Kerman, Kerman, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :