Evaluation of Radiation Treatment Planning By Computed Tomography Metal Artifact Reduction Algorithm
Publish place: Iranian Journal of Medical Physics، Vol: 18، Issue: 6
Publish Year: 1400
نوع سند: مقاله ژورنالی
زبان: English
View: 105
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-18-6_004
تاریخ نمایه سازی: 20 آذر 1400
Abstract:
Introduction: The objective of this study was to evaluate the usefulness of Computed Tomography (CT) images acquired through repeated subtraction reconstruction algorithms to reduce metal artifacts in CT Treatment Planning System (TPS). Material and Methods: Origin images of Gammex phantom and Rando phantom and non-orthopedic metal artifact reduction (O-MAR) images were obtained after high density implantation. O-MAR applied images were also obtained. For evaluation of images, regions of interest (ROI) were set at five tissue rods and three points directly affected by artifacts in Gammex phantom. CT number and noise were compared and analyzed. Based on the investigated results using the Gammex phantom, three virtual cylinder target volumes were set on the Rando phantom to dose change of the radiation treatment planning according to the O-MAR. The average dose was then compared and analyzed. Results: CT number difference according to the application of O-MAR showed significant difference among lung and bone rod and ۳ ROI directly affected. Noise difference according to O-MAR application was significantly different in rod except for bone rod. In the treatment plan using Rando phantom, non-O-MAR and O-MAR images showed -۴.۳ ~ ۱.۹% and -۰.۴ ~ ۲.۳% dose differences, respectively. Conclusion: Applying an O-MAR can reduce image distortion due to high-density implantation, improve image quality, and correct CT numbers.
Keywords:
Authors
Joowan Hong
Department of Radiological sciences, College of Health Sciences, Eulji University, Seongnam-si, Gyeonggi-Do, ۱۳۱۳۵, Republic of Korea
Jihun Choi
Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-Do, ۱۳۶۲۰, Republic of Korea
Jaeouk Ahn
Department of Medical IT Engineering, College of Medical Science, Soonchunhyang University, Asan, Chungnam, ۳۱۵۳۸, Republic of Korea
Kyungjin Kim
Department of Medical IT Engineering, College of Medical Science, Soonchunhyang University, Asan, Chungnam, ۳۱۵۳۸, Republic of Korea
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :