CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

A Study of Indoor Air Quality in Refurbished Museum Building

عنوان مقاله: A Study of Indoor Air Quality in Refurbished Museum Building
شناسه ملی مقاله: JR_CEJ-4-11_007
منتشر شده در November در سال 1397
مشخصات نویسندگان مقاله:

Syahrun Neizam Mohd Dzullkiflli - Faculty of Civil and Environmental Engineering, Universiti Tun Hussein Onn Malaysia, ۸۶۴۰۰ Parit Raja, Batu Pahat, Johor, Malaysia
Abd Halid Abdullah - Faculty of Civil and Environmental Engineering, Universiti Tun Hussein Onn Malaysia, ۸۶۴۰۰ Parit Raja, Batu Pahat, Johor, Malaysia
Lee Yee Youn - Faculty of Engineering, Universiti Malaysia Sarawak, ۹۴۳۰۰ Kota Samarahan, Sarawak, Malaysia
Abdul Mutalib Leman - Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, ۸۶۴۰۰ Parit Raja, Batu Pahat, Johor, Malaysia
Samiullah Sohu - Faculty of Civil and Environmental Engineering, Universiti Tun Hussein Onn Malaysia, ۸۶۴۰۰ Parit Raja, Batu Pahat, Johor, Malaysia

خلاصه مقاله:
Problem related with indoor air quality (IAQ), is rapidly becoming a major health issue as people spend almost ۹۰% of their time indoors. Museums were established in Malaysia more than hundred years ago. Since the year ۲۰۰۵, Malaysia has been moving away from constructing new buildings in favour of refurbishing historic and old ones. A healthy environment at the museum building has been identified as one of the important element that must been considered, but it is not sure either IAQ in the museum building provide a good air quality or not. The purpose of this study is to determine the actual indoor environment of the museum building in Melaka. In this study, the IAQ measurement were conduct for six days at the Melaka Sultanate Palace Museum and at the History and Ethnography Museum. During the measurement, IAQ parameters of gaseous pollutant of nitrogen dioxide, sulfur dioxide and carbon dioxide, and particulate matter of fine particles were recorded by using specific IAQ equipment. The finding of this study indicates that the distance of buildings from roadways appears to have an impact on indoor environmental levels, especially for nitrogen dioxide, sulfur dioxide and particulate matter. Based on the results, only gaseous pollutant of sulfur dioxide had not exceeding the acceptable TLV compared to the other IAQ pollutants.

کلمات کلیدی:
Indoor Air Quality; Museum Building; Refurbished

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1351716/