Ground Coupled Heat Pump Design for Tafila Climate
عنوان مقاله: Ground Coupled Heat Pump Design for Tafila Climate
شناسه ملی مقاله: JR_APRIE-4-3_003
منتشر شده در در سال 1396
شناسه ملی مقاله: JR_APRIE-4-3_003
منتشر شده در در سال 1396
مشخصات نویسندگان مقاله:
Emran. M. Ataykah - Department of Mechanical Engineering, Tafila Technical University, Jordan.
خلاصه مقاله:
Emran. M. Ataykah - Department of Mechanical Engineering, Tafila Technical University, Jordan.
This work represents a theoretical investigation of a ground coupled heat pump system that is used for domestic heating and cooling purposes of a typical residential house in Tafilah-Jordan. The system is designed to provide heating and cooling loads of ۷.۳۹, ۷.۲۷ KW respectively. The designed system consists of a ground buried heat exchanger (۱.۵m depth, ۶.۵m length, and ۲.۲cm diameter), indoor heat exchanger, and a ۲ HP compressor. The system has been analyzed economically and it was found that the ground coupled heat pump system reduces energy consumption and has a payback period for of ۱.۵ years.
کلمات کلیدی: Heat Pump, Energy Saving, Economic Analyses, Residential Building, Heating and Cooling Loads