Influence of wall mounted baffle on suppressing sloshing in a rectangular tank

عنوان مقاله: Influence of wall mounted baffle on suppressing sloshing in a rectangular tank
شناسه ملی مقاله: CAUICNF06_007
منتشر شده در ششمین کنفرانس بین المللی مهندسی عمران، سازه و زلزله در سال 1400
مشخصات نویسندگان مقاله:

Reza Saghi - Msc of Hydraulic engineering, Department of Civil Engineering, Islamic Azad University, Mashhad branch, Mashhad, Iran
Hassan Saghi - Associate professor, Department of Civil Engineering, Hakim Sabzevari University, Sabzevar, Iran

خلاصه مقاله:
In this paper, a numerical model was developed to simulate the sloshing phenomenon in a rectangular tank with a wall mounted baffle. The influence of different parameters including the water filling level, the baffle location, and the baffle length were evaluated on the suppressing sloshing in a rectangular tank. Finally, some suggestions were presented to optimize the efficiency of the baffles. Finally, the wall mounted baffles located at Hb/Ht=۰.۳۵m and Lb/Lt=۰.۲-۰.۲۵ was suggested as the optimum one in which the swash force arises from the sloshing impact was mitigated around ۷۵%.

کلمات کلیدی:
Sloshing, Wall mounted baffle, Sway motion, Entropy generation.