A New Pattern Recognition-Based Method for Non-Communication On-Line Partial Discharge Location in Power Cables

عنوان مقاله: A New Pattern Recognition-Based Method for Non-Communication On-Line Partial Discharge Location in Power Cables
شناسه ملی مقاله: PSC26_030
منتشر شده در بیست و ششمین کنفرانس بین المللی برق در سال 1390
مشخصات نویسندگان مقاله:

A Soltani - Center of Excellence for Power System Automation and Operation- Iran University of Science and Technology (IUST)
S.M Shahrtash - Center of Excellence for Power System Automation and Operation- Iran University of Science and Technology (IUST)

خلاصه مقاله:
In this paper a new method for PD location in power cable is presented which is based on pattern recognition algorithms with features extracted by employing Mathematical Morphology Gradient Algorithm (MMGA). The main advantages of this method are being on-line and having accurate results for PD location in power cable without any need to use a synchronized data at the two ends of cable. Furthermore, the proposed method is compared with two conventional PD location methods including Time Domain- Based and Amplitude-Frequency methods.

کلمات کلیدی:
PD Location, Pattern Recognition Mathematical Morphology, Power cables