CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Entropy Generation and Optimization of Laminar Forced Convection Air Cooling in a Horizontal Channel Containing Heated Sources

عنوان مقاله: Entropy Generation and Optimization of Laminar Forced Convection Air Cooling in a Horizontal Channel Containing Heated Sources
شناسه ملی مقاله: JR_JAFM-10-3_006
منتشر شده در در سال 1396
مشخصات نویسندگان مقاله:

M. Bensouici - Laboratory of Applied Energetics and Pollution, Faculty of Engineering Sciences, Department of Mechanical Engineering, University of Mentouri Brothers-Constantine, Road of Ain El. Bey, Constantine ۲۵۰۰۰, Algeria
F. Z. Bensouici - Faculty of Pharmaceutical Process Engineering, University of Constantine ۳, UV N۰۵, Ali Mendjeli New City, Khroub, Constantine ۲۵۰۰۰, Algeria

خلاصه مقاله:
A forced convection air-cooling of two identical heat sources mounted in a horizontal channel is numerically studied. Four effects of Reynolds number, separation distance, height and width of the components on the flow structure and heat transfer inside the channel have been examined. The entropy generation minimization method (EGM) is employed to optimize the heat transfer and fluid flow in the channel. The flow field is governed by the Navier–Stokes equation and the thermal field by the energy equation. The finite volume method and the SIMPLER algorithm are used to solve the continuity, momentum, energy and entropy generation equations. Results show that the mean Nusselt number increases with increase of the following parameters: Reynolds number, separation distance, height and width of the components. However, these parameters increase the total entropy generation, and thus provokes the degradation of the fan energy. The optimal values of separation distance, height and width heat source are: [(Sopt= ۱ with W=۰.۲۵, C=۰.۲۵, Re=۵۰, η=۱.۱۳۴), (Copt=۰.۳ with W=۰.۲۵, S=۰.۲۵, Re=۱۰۰, η=۰.۸۹۵) and (Wopt= ۰.۱ S=۰.۲۵, C=۰.۲۵, Re=۲۰۰, η=۱.۰۰۴)], respectively, where η is the optimization factor (=Num/S_T^*) and is defined as the ratio of Nusselt number to the total entropy generation. Finally, the optimal and the best configuration for maximum heat transfer and minimum entropy generation is observed at Re=۵۰, S=۱, C=۰.۲۵ and W=۰.۲۵.

کلمات کلیدی:
Numerical simulation, Electronic component cooling, Forced convection, Entropy generation analysis, Optimization procedure

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1382986/