Simulation of a Neutron Detector for Real Time Imaging Applications

Publish Year: 1377
نوع سند: مقاله ژورنالی
زبان: English
View: 86

This Paper With 6 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IJE-11-4_004

تاریخ نمایه سازی: 19 اسفند 1400

Abstract:

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of ۲-۴ ~m, sandwiched properly with two layers of sufficiently thick (-۳۰ ?µm) hydrogenated amorphous silicon (a-Si:H) diodes would have the optimum characteristics. At a threshold setting of ~۷۰۰۰ electrons, the detectors would have efficiency of about ۴۲%. The expected average signal size is about ۱۲۰۰۰ electrons, which is well above the noise. These neutron detectors have very low gamma sensitivity and are very well suited to real time neutron imaging applications. A

Authors

M. Mireshghi

, Sharif University of Technology