Abstract:

Introduction: This work aimed to investigate the use of megavoltage CT (MVCT) images for retrospective planning in high-dose and low-fractionation radiation techniques for Helical Tomotherapy and Linac.Material and Methods: This work used pre-treatment MVCT images for retrospective planning in high-dose hypofractionation of eight hepatocellular carcinoma (HCC) patients using the stereotactic body radiation therapy (SBRT) technique. The dose per fraction was ۵.۵–۸ Gy in ۴–۵ fractions. As the patients were scanned with Helical Tomotherapy (HT) MVCT before each treatment, the selected MVCT images were registered to kVCT for re-contouring, and then the images were exported to HT and Linac for planning. The kVCT scan images were also exported from HT to Linac for planning in Linac. The final plans were compared and analyzed using the following parameters: conformity index (CI), paddick conformity index (PCI), homogeneity index (HI), and organs at risk (OAR) constraints. The dose verification was performed by gamma passing rate (GPR) test using EBT۳ films.Results: CI values ​​were found in the range ۰.۷–۱.۰۰ ( : ۰.۹۵ ± ۰.۰۶۳), PCI values were found from ۰.۸۱ to ۰.۹۶ ( : ۰.۸۷ ± ۰.۰۴), and HI values were found from ۰.۰۲ to ۰.۵۳ ( : ۰.۱۶ ± ۰.۱۲). OAR constraints were clinically acceptable. Distance-to-agreement of ۳mm and dose difference of ۳% was used as GPR criteria for each plan modality.Conclusion: These results suggest that MVCT could be used as an alternative modality for high-dose re-planning in HT and Linac as well as being used for position verification.

Authors

Ahmad Syafi

Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia

Nuruddin Nasution

Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, West Java, ۱۶۴۲۴, Indonesia Department of Radiotherapy, Cipto Mangunkusumo General Hospital, Jakarta, ۱۰۴۳۰, Indonesia

Wahyu Wibowo

Department of Radiotherapy, Cipto Mangunkusumo General Hospital, Jakarta, ۱۰۴۳۰, Indonesia

Hendry Kodrat

Department of Radiotherapy, Cipto Mangunkusumo General Hospital, Jakarta, ۱۰۴۳۰, Indonesia

Supriyanto Pawiro

Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, West Java, ۱۶۴۲۴, Indonesia

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Langen KM, Zhang Y, Andrews RD, Hurley ME, Meeks SL, ...
  • Perna L, Sini C, Cozzarini C, Agnello G, Cattaneo GM, ...
  • Branchini M, Fiorino C, Oca ID, Belli ML, Perna L, ...
  • Yang JD, Hainaut P, Gores GJ, Amadou A, Plymoth A, ...
  • Wang P, Chung N, Hsu W, Chang F, Jang C, ...
  • Hussein M, Clark CH, Nisbet A. Challenges in calculation of ...
  • Hu Y, Byrne M, Archibald-heeren B, Squires M, Teh A, ...
  • نمایش کامل مراجع