Dosimetric Impact of Contrast Medium on Different Photon Energies Using Conformal & IMRT Techniques in the Treatment of Carcinoma Cervix and Its Validation with Indigenous Phantom

Publish Year: 1401
نوع سند: مقاله ژورنالی
زبان: English
View: 99

This Paper With 11 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IJMP-19-2_008

تاریخ نمایه سازی: 21 اردیبهشت 1401

Abstract:

Introduction: Considering the unwanted exposure to organs in the path of the beam, ۴-field (۴F) and subsequently, Intensity-modulated-radiation-therapy (IMRT), is known as the standard mode of treatment of carcinoma cervix. It is routine practice to inject intravenous contrast during simulation scan which elopes after that from the patient body. Therefore, the impact of contrast media should be investigated for radiation dose calculations. Material and Methods: An indigenously made phantom, named as ‘original contrast (OC)’, was used with dimensions ۱۵ x ۱۵ x ۳۰ cm۳. A sleeve was given to place the ionization chamber at the isocentre of the planning target volume (PTV) inside the cylindrical vial of iodinized contrast. Similarly, a virtual phantom was created with similar dimensions in the presence and absence of contrast media, called as ‘virtual contrast (VC)’ and ‘virtual without contrast (VWC)’ phantom. Plans were generated with photon energies (۶MV/۱۰MV/۱۵MV/۶FFF/۱۰FFF) using ۴F and IMRT technique. Plans were evaluated for PTV (D۹۹%, D۱۰%, Dmean) and Bladder & Rectum (V۳۰Gy, V۱۰Gy). Normal-tissue-integral-dose (NTID) and total-monitor-units (TMU) were also evaluated. Results: D۹۹% of the PTV was comparable in VC and VWC phantoms but was decreased for OC phantom. Similarly, D۱۰% was reportedly higher as ۵۴.۰۳ Gy (۴F, ۶ MV), ۵۴.۷۱ Gy (۴F, ۱۵ MV), ۵۵.۷۸ Gy (۴F, ۶ FFF) and ۵۷.۶۴ Gy (۴F, ۱۰ FFF) for OC phantom. D۳۰% of the bladder and also the NTID was lesser for IMRT cases in all the selected phantoms. Additionally, ۴F has shown lesser spillage with ۶MV/۱۵ MV photon beam energies in OC phantom. The ‘total monitor units (TMU)’ required for IMRT plans were significantly higher. Conclusion: The contrast material under-estimates the planned dose yet has an insignificant influence on the dose calculation. Therefore, unnecessary exposure of dual scans should be avoided the use of ۶MV and IMRT technique should be continued in the clinics.

Keywords:

Contrast , Enhanced Intensity , Modulated Box , Technique Photon Beam Carcinoma Cervix

Authors

Deepak Tripathi

Amity School of Applied Sciences, Amity University (AUUP), NOIDA, India

Manindra Bhushan

Amity School of Applied Sciences, Amity University (AUUP), NOIDA, India Division of Medical Physics & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

Girigesh Yadav

Medical Physics Division, Elekta Medical Systems, India

Lalit Kumar

Medical Physics Division & Radiation Oncology Department, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India

Soumitra Barik

Division of Medical Physics & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

Sarthak Tandon

Division of Medical Physics & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

Pawan Kumar

Amity School of Applied Sciences, Amity University (AUUP), NOIDA, India Division of Medical Physics & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

Swarupa Mitra

Division of Medical Physics & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

Munish Gairola

Division of Medical Physics & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Mathur P, Sathishkumar K, Chaturvedi M, Das P, Sudarshan KL, ...
  • Cozzi L, Dinshaw KA, Shrivastava SK, Mahantshetty U, Engineer R, ...
  • Hanks GE. Conformal radiotherapy for prostate cancer. Ann Med. ۲۰۰۰; ...
  • Michele A, Richard S, Adis T. Side Effects of Radiographic ...
  • Siva P. Raman and Elliot K. Fishman. Bladder malignancies on ...
  • Ramm U, Damrau M, Mose S, Manegold KH, Rahl CG, ...
  • Robar JL, Ricco SA, Martin MA. Tumour dose enhancement using ...
  • Brink JA. Use of high concentration contrast media (HCCM): Principles ...
  • Holloway J, Fuller L, Forstner MD. Effect of intravenous contrast ...
  • Choi Y, Kim JK, Lee HS. Influence of intravenous contrast ...
  • Shi W, Liu C, Lu B, Yeung A, Newlin HE, ...
  • ac.uk. London: The Royal College of Radiologists, Inc.; c۲۰۱۲. Available ...
  • Bhushan M, Yadav G, Tripathi D, Kumar L, Kishore V, ...
  • Bhushan M, Yadav G, Tripathi D, Kumar L, Dewan A, ...
  • Lees J, Holloway L, Fuller M, Forstner D. Effect of ...
  • Shibamoto Y, Naruse A, Pukuma H, Ayakawa S, Sugie C, ...
  • Liu AJ, Vora N, Suh S, Liu A, Schultheiss TE, ...
  • Heydarheydari S, Farshchian N, Haghparast A. Influence of the contrast ...
  • Kim HJ, Chang AR, Park YK, Ye SJ. Dosimetric effect ...
  • Rankine AW, Lanzon PJ, Spry NA. Effect of contrast media ...
  • Nasrollah J, Mikaeil M, Omid E, Mojtaba SS, Ahad Z. ...
  • Burridge NA, Rowbottom CG, Burt PA. Effect of contrast enhanced ...
  • Papanikolaou N, Stathakis S. Dose-calculation algorithms in the context of ...
  • Kumar L, Yadav G, Raman K, Bhushan M, Pal M. ...
  • نمایش کامل مراجع