Comparative exergoeconomic and exergoenvironmental analysis of an ejector enhanced flash-binary geothermal system using various organic working fluids

Publish Year: 1401
نوع سند: مقاله کنفرانسی
زبان: English
View: 209

This Paper With 6 Page And PDF and WORD Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ISME30_192

تاریخ نمایه سازی: 29 خرداد 1401

Abstract:

This article proposes and analyses a new modified flash-binary geothermal power system with ejector enhanced dual-pressure evaporation organic Rankine cycle using six organic working fluids including R۶۰۰a, R۶۰۰, R۶۰۱a, R۶۰۱, R۱۲۳۴ze(E), and R۲۴۵fa. Exergoeconomic and exergoenvironmental concepts are used to analyse the system. The major design parameters are considered to assess the cost and environmental impact performances of the system. Parametric assessment indicates that turbine back pressure (P۳) has the highest positive effect on the csystem among the other parameters for all fluids especially for R۲۴۵ within ۹۱.۲۳%. Furthermore, the highest positive effect on the bsystem belongs to high-pressure turbine inlet pressure (P۱۹) for R۶۰۱a within ۲۴.۲۸%. On the other hand, Pump۲ outlet pressure (P۱۳) has the negative effect on the bsystem and csystem for all fluids.

Authors

Nassim Rostami

Department of Mechanical Engineering, Faculty of Engineering, Alzahra University, Tehran, Iran.

Arezoo Sohbatloo

Department of Mechanical Engineering, Faculty of Engineering, Alzahra University, Tehran, Iran.

Fateme Ahmadi Boyaghchi

Department of Mechanical Engineering, Faculty of Engineering, Alzahra University, Tehran, Iran.