Simultaneous Solution Method: Application to an Iranian Southwestern Reservoir and Effect of Different Parameters on the Study

Publish Year: 1386
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,074

This Paper With 9 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

IPEC02_145

تاریخ نمایه سازی: 22 خرداد 1391

Abstract:

One of the useful methods for interpreting and predicting undersaturated reservoirs performance is simultaneous solution. So using this method initial oil in-place and water influx constant of the reservoir can be estimated. NISOC’s program used for simultaneous solution of the initial oil in-place and water influx constant of a southwestern Iranian undersaturated water drive with no gas cap reservoir. Van Everdingen-Hurst unsteady state model used to match aquifer behavior. Sensitivity analyses show that reservoir pressure and PVT data were the most sensitive parameters respectively. Sensitivity analysis also showed that oil in-place is more sensitive respect to reservoir pressure and PVT data than water influx constant. Eventually, the best rD and tD has been estimated 2.5 and 2.5 respectively. Based on chosen rD and tD, initial oil in-place and water influx constant estimated about 1.13 MMMSTB and 4.54E6 bbl/psi respectively.

Authors

m Chahardowli

Student of Sahand Univ. of Tech

b Pourghasem

NISOC, Res. Eng. Dep

a Khanifar

NISOC, Res. Eng. Dep