Comparison of ۹۹mTc-MDP and ۹۹mTc-MIBI whole body scans for diagnosis of widespread skeletal metastases [Persian]

Publish Year: 1381
نوع سند: مقاله ژورنالی
زبان: English
View: 121

This Paper With 6 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IRJNM-10-1_011

تاریخ نمایه سازی: 7 تیر 1401

Abstract:

Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient’s life, both quantitatively and qualitatively, and prevent exacerbation of the disease and disabling complications. In this study, ۲۲ patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with ۹۹mTc-MIBI and ۹۹mTc-MDP whole body scans, in two separate phases. Patients’ diagnoses were as following: Small Round Cell Tumor, Breast carcinoma, Nasopharynx carcinoma and Multiple Myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of ۷۴۰MBq ۹۹mTc-MDP. After a period of ۱ week a whole body scan was carried out by ۹۹mTc-MIBI for all the patients. No treatment such as radiation therapy or chemotherapy was done in this ۱ week interval. The number and intensity of the scan findings were compared visually, according to the three-phase staging, subsequently. Whole body survey with ۹۹mTc-MIBI in ۱۴ out of ۲۲ patients were positive, demonstrating only ۴۴.۴% of bony lesions established on whole body bone scan with ۹۹mTc-MDP. The mean value of intensity of radiotracer uptake, was around ۱.۵+ (Mild to moderate). On the other hand in ۷ patients with positive ۹۹mTc-MIBI scan some hidden soft tissue lesions (Mostly lymph nodes) were detected with intensity of ۲+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with ۹۹mTc-MIBI whole body scan. The singnificance of ۹۹mTc-MIBI scan is mainly limited to some equivocal of soft tissue lesions.

Authors

Mojtaba Ansari

Nuclear Medicine Division, Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Mohammad Hoshiari

Nuclear Medicine Division, Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Seyed Hossein Mortazavi

Nuclear Medicine Division, Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran