Applied Fluid Mechanics: Laboratory Investigation of Head Losses in DifferentCentrifugal Pump Configurations
Publish place: The Second International Conference on the Application of Materials and Advanced Manufacturing in Industries
Publish Year: 1401
نوع سند: مقاله کنفرانسی
زبان: English
View: 250
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
IAAMM02_021
تاریخ نمایه سازی: 17 مرداد 1401
Abstract:
This paper presents the results of the experimental measurements of the head losses in differentCentrifugal pump configurations such as single, parallel, and series. In every case, pumps are identical,and the average flow rate ranges from ۴ to ۱۹ L/min. During measurements, the inlet and outlet pressuresof pumps were recorded. Additionally, by using the Bernoulli equation, theoretical pump head loss wascollected. Since using pumps in different set ups important in different practical equipment, thisexperiment help provides more information about the characteristics, flow rate, and head loss changes ofdifferent settings.
Keywords:
Authors
Aboutaleb Karami
B.S. in mechanical engineering, University of Tehran, Tehran, Iran;
Shayegan Shahed Haghighi
B.S. in mechanical engineering, University of Tehran, Tehran, Iran;
Javad Marzbanrad
Faculty at School of Automotive Engineering, Iran University of Science and Technology, Tehran, Iran