Combined association of liver and renal injury by intra-aortic balloon pump malposition

عنوان مقاله: Combined association of liver and renal injury by intra-aortic balloon pump malposition
شناسه ملی مقاله: JR_RYA-14-3_007
منتشر شده در در سال 1397
مشخصات نویسندگان مقاله:

Feridoun Sabzi - Kermanshah Cardiovascular Research Centre, Kermanshah University of Medical Sciences, Kermanshah, Iran
Aghigheh Heidari - Department of Anesthesiology, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran
Reza Faraji - Kermanshah Cardiovascular Research Centre, Kermanshah University of Medical Sciences, Kermanshah, Iran

خلاصه مقاله:
BACKGROUND: We report an unusual visceral complication of intra-aortic balloon pump (IABP) due to the malpositioning of the catheter in the aorta.CASE REPORT: A ۵۵-year-old man with severe left ventricular dysfunction underwent coronary artery bypass grafting (CABG) with the preoperative use of an intra-aortic balloon pump. Postoperative course was complicated by renal and hepatic failure. The early occurrence of complications during ۳۶ hours after operation exhibited a serious vascular complication. The combination of acute renal and hepatic failure led to the suspension to occlusive effect of intra-aortic balloon pump catheter on ostium of the aforementioned organs. The intra-aortic balloon pump was removed, and urine output immediately restored. Thereafter, daily slop dawn serum levels of aminotransferases were started, and became normal at the ۱۰th day of operation.CONCLUSION: This is an exceptional case that shows how intra-aortic balloon pump may be contributed to mechanical aortic side branches obstruction. A high index of suspension is mandatory in the diagnosis of such bizarre complications. 

کلمات کلیدی:
Liver, Ventricular Dysfunction, Coronary Artery Bypass

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1504707/