Concurrent Determination of Reliability and Validity of Force Platform, Danesh Salar-e Iranian, Using Kistler's Platform in Measuring Static Balance of Men and Women Athletes; A Descriptive-Surveying Study

عنوان مقاله: Concurrent Determination of Reliability and Validity of Force Platform, Danesh Salar-e Iranian, Using Kistler's Platform in Measuring Static Balance of Men and Women Athletes; A Descriptive-Surveying Study
شناسه ملی مقاله: JR_JRRS-14-6_006
منتشر شده در در سال 1398
مشخصات نویسندگان مقاله:

سارا علی جانی - دانشجوی کارشناسی ارشد، گروه تربیت بدنی و علوم ورزشی، دانشکده تربیت بدنی و علوم ورزشی، واحد اصفهان (خوراسگان)، دانشگاه آزاد اسلامی، اصفهان، ایران
زهره مشکاتی - دانشیار، گروه تربیت بدنی و علوم ورزشی، دانشکده تربیت بدنی و علوم ورزشی، واحد اصفهان (خوراسگان)، دانشگاه آزاد اسلامی، اصفهان، ایران
ابراهیم صادقی دمنه - دانشیار، گروه اعضای مصنوعی و وسایل کمکی، دانشکده علوم توان بخشی و مرکز تحقیقات اختلالات اسکلتی عضلانی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران

خلاصه مقاله:
Introduction: The aim of the current research was to concurrently determine the reliability and validity of force platform device, Danesh Salar-e Iranian, using Kistler's platform device in measuring the static balance of men and women athletes.Materials and Methods: Participants consisted of ۵۰ athletes (۲۵ men and ۲۵ women) from Isfahan City, Iran, who were selected using a purposive convenience sampling method. The research instrument included the force platform device of Danesh Salar-e Iranian model and Kistler's platform device. The subjects tried to keep their static balance on each of the force platforms for ۴۰ seconds with eyes open and eyes closed. After ۴۸-۷۲ hours, test-retest was done under the same conditions as the first test. Each test repeated three times. To measure internal and time reliability, the within-group and between-group correlation tests were used. To measure the concurrent validity, the Pearson correlation test was used. The significance level was set at P < ۰.۰۵. Results: Kistler's platform had internal reliability in all open- and closed-eyes parameters; while the Danesh Salar-e Iranian force platform had internal reliability in all closed-eyes parameters. Both the force platform deviceshad time stability in all open-eyes parameters. Kistler's platform had time stability in all closed-eyes parameters (except total oscillation), too. In addition, there was a significant correlation in all variables between the two force platform devices.Conclusion: Danesh Salar-e Iranian force platform is a valid and reliable equipment to measure the static balance in men and women athletes in most parameters. Technical improvements of the equioment can increase the psychometric parameters of this tool, as well as its usability and effectiveness. This can promote national production, and pave the way for economic growth, national efficiency, and emancipation of dependency.

کلمات کلیدی:
تعادل ایستا, روایی, پایایی, صفحه نیروسنج, ورزشکار

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1592801/