CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Determination of Bisphenol A in Packed Milk and Mineral Water Samples Marketed in Tabriz (Iran) in ۲۰۲۰ Using High-performance Liquid Chromatography-ultraviolet Detector

عنوان مقاله: Determination of Bisphenol A in Packed Milk and Mineral Water Samples Marketed in Tabriz (Iran) in ۲۰۲۰ Using High-performance Liquid Chromatography-ultraviolet Detector
شناسه ملی مقاله: JR_ANALCH-8-4_008
منتشر شده در در سال 1400
مشخصات نویسندگان مقاله:

Amin Rostamzadeh - Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
Mahboob Nemati - Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Department of Pharmaceutical and Food Control, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
Mir Ali Farajzadeh - Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. Engineering Faculty, Near East University, ۹۹۱۳۸ Nicosia, North Cyprus, Mersin ۱۰, Turkey
Mohammad Reza Ashar Mogaddam - Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran

خلاصه مقاله:
Bisphenol A is a monomer used in production of several plastic resins in food storage containers. Residue of BPA in plastics can be found in foods filled into the containers. Due to this fact that BPA is an endocrine disruptor, its dietary exposure must be estimated. In this method, the analyte was extracted using a dispersive liquid-liquid microextraction procedure from water and milk samples. For this purpose, a mixture of acetone and chloroform (۱۴۲ µL) was dispersed into the water sample or aqueous phase obtained from milk after its deproteinization with trichloroacetic acid. In both samples, the obtained cloudy solutions were centrifuged and the sedimented phase analyzed by high performance liquid chromatography-ultraviolet detector. Analytical features of the method consist of limits of detection (۰.۴۴ ng mL-۱ in water and ۰.۵۱ ng mL-۱ in milk samples) and quantification (۱.۴۷ ng mL-۱ in water and ۱.۷۲ ng mL-۱ in milk samples), linearity (r۲=۰.۹۹۲), precision (RSD≤۱۱.۱%), and accuracy (RSD≤۳%) were studied under final conditions. The results showed that the obtained results are acceptable. Different milk and water samples were analyzed using the developed method and BPA was found in several samples in the ranges of ۱۱.۲-۳۲.۶ and ۹.۶-۲۳.۵ ng mL-۱ in milk and water samples, respectively. Comparing the results with maximum residue limit established by European Commission showed that BPA content was higher than the permitted level.

کلمات کلیدی:
Bisphenol A, High-performance liquid chromatography, Water, Milk, Dispersive liquid-liquid microextraction

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1598190/