Application of Quartz Crystal Nanobalance for Simultaneous Determination of Vanillylmandelic Acid and Homovanillic Acid by a Net Analyte Signal Based Method

Publish Year: 1387
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,212

متن کامل این Paper منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل Paper (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ICNN02_169

تاریخ نمایه سازی: 27 شهریور 1391

Abstract:

Urinary homovanillic acid (HVA) and vanillylmandelic acid (VMA) are quantitatively the most important catabolic products of catecholamines. Increased levels of these metabolites in urine clinically may indicate the presence malignant tumors arising from cells of the neural crest such as neuroblastoma and pheochromocytoma [1].Quartz crystal nanobalance (QCN) is a sensing system based on the sorption of analyte on an adsorbent material. The QCN comprises a thin vibrating AT-cut quartz wafer sandwiched between two metal excitation electrodes. When small amounts of mass are adsorbed at the quartz electrode surface, the frequency of the quartz is changed according to the well-known Sauerbrey equation [2]:[]FFAmqqΔ−=Δ202/12)(μρ Eq. (1)where ΔF is the measured frequency shift, Δm the mass change, F0 is the fundamental resonant frequency of the unloaded quartz crystal (10 MHz), A is the electrode area (0.21 cm2), ρq is the density of quartz (2.65 g cm-3) and μq is the shear modulus of quartz (2.95*1011 dyn cm-2). With these constants, we obtain:)(926.0)(HzFngmΔ−=Δ Eq. (2)The major drawback of the some sensors based on QCN is lack of selectivity since other compounds usually interfere along with the analyte. To overcome this shortcoming, considerable interest has been raised on the use of quartz crystals as sensor in conjunction with associated pattern recognition techniques in distinguishing various kinds of compounds [3].In the current investigation the simultaneous determination of VMA and HVA in the solution containing some common urine compounds is described using polymethylmethacrylate (PMM) coated QCN. Net analyte signal (NAS) is utilized to process the frequency data of the crystal at various times, based on different adsorption dynamics of VMA and HVA on the PMM coated QCN

Authors

A Mirmohseni

Polymer Research Technology Laboratory, Faculty of Chemistry, University of Tabriz, Tabriz

M Shojaei

Animal Biology Department, Faculty of Natural sciences, University of Tabriz, Tabriz, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • J.L. Young, L.G. Ries, E. Silverber, J.W. Horm, R.W. Miller, ...
  • G. Z. Sauerbrey, Phys. 155, 206-222, 1959. ...
  • B. Sellergren, , R. N. Karmalkar, K. J. Shea, J. ...
  • نمایش کامل مراجع