Combined Analysis of Breast Morphometry, Compression and Volumetric Breast Density: Valuable Input to Improve Mammography Screening Using International Bench Marking

عنوان مقاله: Combined Analysis of Breast Morphometry, Compression and Volumetric Breast Density: Valuable Input to Improve Mammography Screening Using International Bench Marking
شناسه ملی مقاله: JR_IJMP-20-3_001
منتشر شده در در سال 1402
مشخصات نویسندگان مقاله:

Youssef Bouzekraoui - Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco
Hilde Bosmans - KU Leuven, Faculty of Medicine, Department of Imaging and Pathology, Medical Physics and Quality Assessment, Belgium.
Lesley cockmartin - Universitair Ziekenhuis Leuven
Mauro campoleoni - Fondazione IRCCS Ca&#۰۳۹; Granda Ospedale Maggiore Policlinico: MILANO, Italy
sanae Douama - Laboratory of high energy physics Modelisation Simulation, Faculty of Sciences, University Mohammed V, Rabat, Morocco
imane Ou-saada - Laboratory of high energy physics Modelisation Simulation, Faculty of Sciences, University Mohammed V, Rabat, Morocco.
FARIDA BENTAYEB - Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco

خلاصه مقاله:
Introduction: The aim of this study was to select parameters from a combined analysis of breast compression, breast morphometry and volumetric breast density, telling about the overall quality of breast positioning, and to apply these investigations on a Moroccan population at the start of new breast cancer screening activities. The study found that compression force in mammography varies greatly and has no specific limit. The researchers attempted to find correlations between compression force and mammographic factors to establish a range of values for standardized compression in mammography.Material and Methods: The study was carried out in a university hospital, a candidate screening center, provided with new technology equipment, qualified staff and doctors of different specialties. Image acquisition was procured on a FFDM Siemens Inspiration system for ۲۵۰ patients in diagnostic mammography and all patients’ information was collected. The data about dose, the compression force and the thickness of the compressed breast were obtained directly from the DICOM header information, applying Volpara Density software.Results: The results show a correlation between compression force and breast density. The volume of breast tissue compared to the total volume of the breast (VBD) decreased with increasing compressed breast thickness (CBT) and age. The mean VBD was ۹.۳% ± ۶%, the compression force was ۷۱±۱۵ N and the CBT was ۵۳±۱۱ mm.Conclusion: The global analysis and comparison of mammographic parameters showed good similarity between Moroccan and the previous studies population. The mammographic techniques can therefore be used to Moroccan screening programs.

کلمات کلیدی:
Mammographies, Digital Mammography, Mammographic Breast Density