CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Design and implementation of radon detector for remote areas by using photocell and GSM

عنوان مقاله: Design and implementation of radon detector for remote areas by using photocell and GSM
شناسه ملی مقاله: EMAECONF02_008
منتشر شده در دومین کنفرانس برق، مکانیک ،هوافضا، کامپیوتر و علوم مهندسی در سال 1402
مشخصات نویسندگان مقاله:

Bahareh Sabetan - Master of Nuclear Engineering shiraz university
Kamal Hadad - Professor Department Nuclear Engineering Shiraz University

خلاصه مقاله:
Radon poses serious health risks especialy in remote areas. Low-cost sensor devices have emerged as a promising technology, but their reliability is still unknown. Therefore, this research, a semi-conductor detector using a photodiode and a transistor has been made to monitor and detect radon and its decomposition products in different and even remote places, which provides information on the level of radon in real time. It is transmitted by a GSM system to a data transmitter.To evaluate the detector, soil containing natural uranium is placed in a closed chamber to reach a stable equilibrium. The field count level was recorded for different activity levels and different counting times and the detector was exposed to uranium soil. The results show that the counts are proportional to the counting time and activity levels and the detector can be calibrated to a standard radon source.

کلمات کلیدی:
Radon detector, detector construction, remote area monitoring, photocell, GSM module

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1680431/