CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Wearable Wireless Sensors for Measuring Calorie Consumption

عنوان مقاله: Wearable Wireless Sensors for Measuring Calorie Consumption
شناسه ملی مقاله: JR_JMSI-10-1_003
منتشر شده در در سال 1399
مشخصات نویسندگان مقاله:

Faranak Fotouhi-Ghazvini - Department of Computer Engineering and IT, Faculty of Engineering, University of Qom, Iran
Saedeh Abbaspour - Department of Computer Engineering and IT, Faculty of Engineering, University of Qom, Iran

خلاصه مقاله:
Background: The tracking devices could help measuring the heart rate and energy expenditure and recognizing the user’s activity. The calorie measurement is a significant achievement for the fitness tracking and the continuous health monitoring. Methods: In this paper, a combination of an accelerometer and a photoplethysmography (PPG) sensor is implemented to calculate the calories consumed. These sensors were mounted next to each other and then were placed on the ankle and finger by flat cable. The sensed data are transferred via Bluetooth to a smartphone in a serial and real‑time manner. An Android App is designed to display the user’s health data. The average amount of consumed energy is obtained from the combination of the accelerometer sensor based on the laws of motion and the PPG sensor based on the heart rate data. Results: The designed system is tested on ۱۰ nonathlete males and ۱۰ nonathlete females randomly. By applying the wavelet, the value of the acceleration signal variance was reduced from ۳.۲ to ۰.۸. The correlation between PPG and pulse oximeter was ۰.۹. Moreover, the correlation of the accelerometer and treadmill was ۰.۹. The root mean square error (RMSE) and the P value of the calorie output from PPG and pulse oximeter are ۰.۵۳ and ۰.۰۰۸, respectively. The RMSE and the P value of the calories output from the accelerometer and the treadmill are ۰.۴۲ and ۰.۰۰۷, respectively. Conclusion: Our device validity and reliability were good by comparing it with a typical smart band, smart watch, and smartphone available in the market. The combined PPG and the accelerometer sensors were compared with the gold standard, the pulse oximeter, and the treadmill. According to the results, there is no significant difference in the values obtained. Therefore, a mobile system is augmented with the wireless accelerometer and PPG that are connected to a smartphone. The system could be carried out with the user at any time and any place.

کلمات کلیدی:
Accelerometer, activity monitoring, calorie consumption, photoplethysmography, smartphone health application

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1700084/