Cyclic fatigue resistance of three Nickel-Titanium rotary files in single curvature canals: An in-vitro analysis

عنوان مقاله: Cyclic fatigue resistance of three Nickel-Titanium rotary files in single curvature canals: An in-vitro analysis
شناسه ملی مقاله: JR_JDMT-12-3_004
منتشر شده در در سال 1402
مشخصات نویسندگان مقاله:

Kiranmurthy Dhananjaya - Department of Conservative Dentistry and Endodontics, Vananchal Dental College and Hospital, Garhwa, India
Amitu Singh - Department of Pedodontics and Preventive Dentistry, Vananchal Dental College and Hospital, Garhwa, India
Nilotpol Kashyap - Department of Pedodontics and Preventive Dentistry, Vananchal Dental College and Hospital, Garhwa, India
Shreya Rani - Department of Pedodontics and Preventive Dentistry, Vananchal Dental College and Hospital, Garhwa, India
Soni Patel - Department of Pedodontics and Preventive Dentistry, Vananchal Dental College and Hospital, Garhwa, India
Nishi Singh - Department of Pedodontics and Preventive Dentistry, Vananchal Dental College and Hospital, Garhwa, India

خلاصه مقاله:
Objective: This study aimed to evaluate the cyclic fatigue resistance (CFR) of three different heat-treated nickel-titanium (NiTi) files in rotary motion utilizing a cyclic fatigue testing device.Methods: Three NiTi rotary systems, Hero Gold, NeoEndo Flex, and T-Pro were used in this study. Ten files from each system (۴% taper, #۲۵ size, ۲۱mm length) were tested for CFR. The test was conducted in an artificial canal in a customized cyclic fatigue device. The canal system is comprised of a ۶۰° angle of curvature located ۸ mm from the orifice. All files were rotated until fracture at the rotation per minute (RPM) and torque settings according to the manufacturer's recommendation. The time to fracture (TTF) was recorded in seconds for each instrument and then multiplied by (RPM/۶۰) to obtain the number of cycles to fracture (NCF). The fracture length of each instrument fragment was recorded. Data were analyzed by one-way ANOVA and Tukey test and P-value <۰.۰۵ was considered statistically significant.Results: The NiTi rotary systems demonstrated significantly different TTF values (P=۰.۰۰۱). Hero Gold exhibited a significantly higher TTF (۱۱۴.۱۳±۴.۲۱), followed by NeoEndo Flex (۶۵.۲۴±۲.۲۰) and T-Pro (۴۰.۵۰±۳.۴۵). The difference in TTF was also significant between NeoEndo Flex and T-Pro groups (P<۰.۰۵). There was no statistically significant difference in the length of the fractured fragments between the three groups (P=۰.۰۸).Conclusion: The Hero Gold file system demonstrated significantly superior CFR compared to the NeoEndo Flex and T-Pro systems, possibly due to differences in manufacturing processes for different file systems.

کلمات کلیدی:
Endodontics, Fatigue, file fracture, Root canal preparation, Root Canal Therapy, Rotary files