CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Experimental Study to Evaluate Antisymmetric Reinforced Concrete Deep Beams with Openings under Concentrated Loading Using Strut and Tie Model

عنوان مقاله: Experimental Study to Evaluate Antisymmetric Reinforced Concrete Deep Beams with Openings under Concentrated Loading Using Strut and Tie Model
شناسه ملی مقاله: JR_IJE-36-12_017
منتشر شده در در سال 1402
مشخصات نویسندگان مقاله:

A. S. J. Al-Zuheriy - Civil Engineering Department, University of Technology – Iraq, Baghdad, Iraq

خلاصه مقاله:
The Strut-and-Tie modeling (STM) technique represents an applicable and valuable method for structural engineers to design disturbed regions (D-regions) of reinforced concrete structures where the assumption of plane sections remaining plane after loading is inapplicable. The most important aspect to guarantee the suitable structural and economic performance of the design is finding a suitable truss-analogy model, leading to the use of a more efficient model in structural buildings. The evaluation of the antisymmetric Strut-and-Tie models (STM) with openings under different concentrated external loads has not been comprehensively investigated in the literature. So, to address this gap, the goal of this paper is to achieve the most efficient reinforcement layout design in antisymmetric reinforced concrete deep beams with openings under concentrated loading using the strut and tie model.  The experimental work was conducted and included (۳) antisymmetric reinforced concrete deep beams with openings that were tested under different concentrated loadings (۲۵, ۳۵, and ۱۶ kips for Specimens ۱, ۲, and ۳, respectively) using the strut and tie model. The ANSYS FEM software is used for the initial strut and tie analysis, and the RISA-۳D structural analysis program is used to find the internal forces for all members under concentrated external loads in each specimen. The findings of this paper show that Specimen ۱ had the highest efficiency of ۱.۶۷, while Specimen ۳ had the lowest efficiency of ۱.۳۱. It can be concluded that the efficient reinforcement layout of the strut and tie model leads to the highest efficiency of the model, regardless of the value of the externally applied load.

کلمات کلیدی:
Strut-and-Tie Models, Crack Patterns, Load Deflection Analysis, Concentrated Loading, Strut Reinforcement, Deep Beams

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1792771/