CIVILICA We Respect the Science
(ناشر تخصصی کنفرانسهای کشور / شماره مجوز انتشارات از وزارت فرهنگ و ارشاد اسلامی: ۸۹۷۱)

Evaluation of tendon healing using fibroblast like synoviocytes in rabbits: A biomechanical study

عنوان مقاله: Evaluation of tendon healing using fibroblast like synoviocytes in rabbits: A biomechanical study
شناسه ملی مقاله: JR_VRFAN-7-1_004
منتشر شده در در سال 1395
مشخصات نویسندگان مقاله:

Mahboobeh Azad-Tirgan - Department of Surgery and Diagnostic Imaging, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran
Farshid Sarrafzadeh-Rezaei - Department of Surgery and Diagnostic Imaging, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran
Hassan Malekinejad - Department of Basic Sciences, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran
Rahim Hobbenaghi - Department of Pathobiology, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran
Behnam Heshmatian - Neurophysiology Research Center, Urmia University of Medical Sciences, Urmia, Iran

خلاصه مقاله:
Tendon never restores the complete biological and mechanical properties after healing. Several techniques are available for tissue-engineered biological augmentation for tendon healing like stem cells. Recently, synovium has been investigated as a source of cells for tissue engineering. In the present study, we investigated potentials of fibroblast like synoviocytes (FLSs) in tendon healing. Sixteen rabbits were divided randomly into control and treatment groups. One rabbit was used as a donor of synovial membrane (synovium). The injury model was unilateral complete transection through the middle one third of deep digital flexor tendon (DDFT). Subsequently, the tendon stumps were sutured with ۳/۰ nylon. In treatment group, ۰.۱ mL phosphate-buffered saline (PBS) solution containing ۱ × ۱۰۶ nucleated cells of FLSs was injected intratendinously at both tendon stumps just next to incision line. In control group, ۰.۱ mL PBS without FLSs was used for intratendinous injection. Model animals were euthanized at eight weeks, DDFTs were harvested and prepared for biomechanical study. Results of study showed that, there was no significant differences in biomechanical parameters values between FLSs treated and control groups. In conclusion, intratendinous injection of FLSs did not improve biomechanical properties during eight weeks in rabbit.

کلمات کلیدی:
Biomechanical properties, Fibroblast like synoviocytes, Rabbit, Tendon

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1818136/