Early detection of epoxy coated St-۳۷ underlying corrosion by fluorescent indicator

عنوان مقاله: Early detection of epoxy coated St-۳۷ underlying corrosion by fluorescent indicator
شناسه ملی مقاله: JR_ICAC-5-17_002
منتشر شده در در سال 1394
مشخصات نویسندگان مقاله:


خلاصه مقاله:
In the present work, the application of ۸-hydroxyquinoline (۸-HQ) as a ferric ion sensitive indicator, in epoxypolyamine coating was investigated. Having turn-on mechanism and showing no prematurely fluorescence when mixed with the coating precursors make ۸HQ useful for detecting undercoating corrosion of St-۳۷ which is covered by epoxy coating. The effect of different concentrations of ۸HQ(۰.۰۵,۰.۱,۰.۵,۱w.t%) in epoxy coating, on corrosion detection, optical, electrochemical and adhesion properties of applied coating were studied respectively by fluorescence microscopy, UV- Visible spectroscopy, electrochemical impedance spectroscopy and Pull-off methods. In the process, the sample with ۰.۱w.t% of ۸HQ not only, showed acceptable corrosion detection performance, but also was good in optical, electrochemical and adhesion properties.

کلمات کلیدی:
۸-hydroxyquinoline, Corrosion indicator, Epoxy coating, Fluorescence microscope, Electrochemical Impedance Spectroscopy, ۸-هیدروکسی کوئینولین, شناساگر خوردگی, پوشش اپوکسی, میکروسکوپ فلورسنس, آزمون امپدانس الکتروشیمیایی؛

صفحه اختصاصی مقاله و دریافت فایل کامل: https://civilica.com/doc/1831706/